MIL-PRF-39012 Spec. Parts

Page 1 of 3
NSN 5985-01-613-1725 Fixed Attenuator

Material Spec:

Sma female conn. Per mil-prf-39012 on both ends of attenuator

NSN 5935-01-588-0328 Coaxial Test Adapters

Material Spec:

Constructed from gold-plated beryullium copper and stainless steel; 50 ohm; dc to 18 ghz; 0.15 db insertion loss and 1.40: 1 vswr at 18 ghz; conforms to mil-prf-39012; type: n-plug-tnc jack

NSN 5996-01-557-1114 Radio Frequency Amplifier

Material Spec:

Amplifiers shall be supplied with two sma female connectors, mil-prf-39012

NSN 5935-01-552-4360 Electrical Plug Connector

Material Spec:

81349-mil-prf-39012 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).

NSN 5995-01-550-6185 Radio Frequency Cable Assembly

Material Spec:

Next assembly:196805-01; drawing number:196763; this procurement control drawing describes the requirements for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment; the cable length shall be 97.83 to 98.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; the insertion shall be less than 8.5 db, maximum at 2.0 ghz; required connector per mil-prf 39012, p1:ptnc male, straight, passivated stainless steel, p2:ptnc male, straight, pasivated stainless steel; the cable shall with stand a pull test of 80 lbs. Minimum per mil-prf-39012

NSN 5995-01-550-6184 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w2; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6182 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w9; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6181 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w8; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6180 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w6; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6179 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w7; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6178 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w5; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6177 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w4; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6176 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w3; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment

NSN 5995-01-550-6175 Radio Frequency Cable Assembly

Material Spec:

Connector pull test:80 lbs. Minimum per mil-prf-39012; next assembly:196805-01; cable label:w1; drawing number:196781; length shall be 74.83 to 75.83 feet of continuous coaxial cable; the maximum vswr will be 1.40:1, 50 ohm impedance; attenuation:the insertion loss shall be less than 17.0 db, maximum at 18.0 ghz; this procurement control drawing describes the requirement for ultra low loss rf coaxial cable assembly terminated with tnc connectors; the cable will be used in a marine environment