6525-01-217-5575

Medical Radiographic X-ray Apparatus email this page
ITAR Registered

Model or part number: 5-603

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
In reusable container; optional accessories c/o portable radiographic table; stand alone battery pack charger and sinus extension cone

pdf NSN 6525-01-217-5575 Datasheet

MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Control unit w/displays 1; high voltage transformer 1; tubestand 1; tube assembly 1; collimator 1; control cabinet 1; rough terrain drive system and chassis 1; battery charging system 1 and battery pack 1
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
20.0
MRC:
Indicates the design type of the item.APGF
Design Type:
Mobile
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Single focus
MRC:
Indicates the type of rectification provided.BPKZ
Rectification Type:
Full-wave
MRC:
The means of cooling used to maintain the required operating temperature of the tube.CLPG
Tube Cooling Method:
Air and oil
MRC:
Indicates the type of mount utilized to support the tube.CLPH
Tube Mounting Type:
Tube stand
MRC:
Indicates the type of mount utilized to support the tube stand.CLPR
Tube Stand Mounting Type:
Any acceptable
MRC:
The means used for rectifying the transformer.CLQD
Transformer Rectification Method:
Self-rectifying
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Xray apparatus mobile sngl focus: 120/230v50/60hz20amps
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0 and 230.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0
MRC:
--
NIIN:
012175575
MRC:
--
NATO Stock Number:
6525-01-217-5575
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
T140-C
MRC:
--
INC:
06320
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6525-01-217-5575

A portable, mobile, or stationary device usually consisting of an x-ray tube, transformer, control, and associated devices designed for radiographic examination of patients.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9022140000
NAICS:
334517
End Use Class:
21610
SITC:
77421
USDA:
1
HITECH:
2

Schedule B Codes Definitions:

Schedule B 9022140000

Rays For Medical, Surgical, Or Veterinary Uses, Nesoi Apparatus Based On The Use Of X

End Use Code 21610

Medicinal Equipment

Standard Intl. Trade Class (SITC) 77421

Rays, Whether Or Not For Medical, Surgical, Dental Or Veterinary Use (including Radiography Or Radiotherapy Apparatus) Apparatus Based On The Use Of X

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
063560
NMF Description:
X-ray Machine
UFC:
98185
LTL:
Rating variable
LCL:
--
WCC:
656
TCC:
Z
SHC:
9
ADC:
A
ACC:
M

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 656

X-ray apparatus and equipment.

Air Commodity (ACC) M

Medical supplies, equipment, samples, records, etc..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide