Part Number OA-772

Radiacmeter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
oa-772
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
010763912
NSN
National Stock Number:
6665-01-076-3912 6665010763912
TXT
Description:
Radiacmeter
INC
INC
Item Name Code:
07833
INC
COM
Compliance:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
300.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
150.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
150.0 millimeters
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The means of attaching the item.ADJH
Mounting Method:
Portable
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Instantaneous individual detection of air ionization by alpha particles ejected during a radioactive radon decay event
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Chronometer
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Alpha rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Alpha rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Ionization chamber
MRC:
An indication of whether or not the item is portable.APCB
Portability:
Portable
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
Not rated
MRC:
The minimum and maximum number of single responses per minute.APPK
Count Range Per Minute:
+0.0/+1200.0
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
Not rated
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
Not rated
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0