2925-00-294-1902

Engine Generator Cutout Relay email this page
ITAR Registered

Model or part number: A791BB

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Electrical Cutout NSN 2925-00-294-1902.

pdf NSN 2925-00-294-1902 Datasheet

MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
8
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Stud
MRC:
An indication of whether or not a frame is included.ABWP
Frame:
Any acceptable
MRC:
The value of the current flowing through the item when operated at its designed voltage,expressed in amperes.AFSS
Design Current Rating In Amps:
1000.0
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4
MRC:
An indication of whether or not shielding against radio interference is provided.ALBH
Radio Interference Shielding:
Not provided
MRC:
The distance between the mounting facilities.ARKQ
Mounting Facility Spacing:
3.000 in. By 4.500 in. Mtg c
MRC:
Designates the size of the mounting facility.AWYX
Mounting Facility Size:
0.196 in. Dia
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
The electrical voltage of the system for which the item is designed.AXHT
Voltage System For Which Designed:
28.0 volts
MRC:
The cut-in voltage/s/ required to close the circuit.AXHZ
Cut-in Voltage Rating:
24.0 volts
MRC:
The cutout voltage/s/ required to open /break/ the circuit.AXMN
Cutout Voltage Rating:
18.0 volts
MRC:
The discharge current(s) required to open (break) the current.AXMR
Cutout Current Rating:
Between 25.0 amperes and 50.0 amperes
MRC:
--
NIIN:
002941902
MRC:
--
NATO Stock Number:
2925-00-294-1902
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
T130-J
MRC:
--
INC:
17181
MRC:
--
IMM:
CX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 2925-00-294-1902

A device for automatically opening the circuit between an engine generator and the battery of the engine electrical system to prevent the flow of reverse current to the generator and automatically closing the circuit when the voltage of the generator reaches normal range. Excludes regulator, current and relay (as modified).

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
5.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
41
PKG:
15A0
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 41

Watervaporproof bag, sealed.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8803909060
NAICS:
336419
End Use Class:
50070
SITC:
79297
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8803909060

Other Parts, Nesoi, For Use In Other Military Aircraft, Spacecraft and Spacecraft Launch Vehicles (excluding Parts Of Communication Satellites)

End Use Code 50070

Type Goods Parts For Military

Standard Intl. Trade Class (SITC) 79297

Parts Of Aircraft and Associated Equipment, Spacecraft (including Satellites) and Spacecraft Launch Vehicles, N.e.s.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061540
NMF Description:
Cut-outs/parts Noi In Box/crate
UFC:
34520
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
Z
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) Z

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »