About this product
Cooling tower-not incl.;accessories-incl.;1st motor-4.000 hp,2nd motor-0.500 hp,3rd motor-0.500 hp

Description

Environmental Control Unit NSN 4120-00-613-8060.

pdf NSN 4120-00-613-8060 Datasheet

MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wall
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Compressor, condenser, evaporator
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
208.0 volts
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Freon-12
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The number of electric motors provided.AWLX
Electric Motor Quantity:
3
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Air
MRC:
Indicates the type of compressor unit for which the item is designed.AZSD
Compressor Unit Type:
Closed
MRC:
The nominal capacity of the item to cool.AZSF
Cooling Capacity:
650.0 cubic feet per minute
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Evaporative condenser
MRC:
The chemical compound or mechanical mixture properties of which the cabinet is fabricated.CYGG
Cabinet Material:
Aluminum-copper free
MRC:
The capacity of the item to cool,expressed in british thermal units per hour.CYJE
Cooling Capacity In Btu Per Hour:
20500.0
MRC:
The capacity of the item to heat,expressed in british thermal units per hour.CYKM
Heating Capacity In Btu Per Hour:
17500.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
--
NIIN:
006138060
MRC:
--
NATO Stock Number:
4120-00-613-8060
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A505G0
MRC:
--
INC:
06486
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4120-00-613-8060

A self-contained unit designed to perform the functions of cooling, circulating, filtering, dehumidifying or otherwise processing of air. It may also be equipped to perform the additional functions of heating or humidifying. It may be the air cycle type used in aircraft or the vapor cycle type applicable to ground or aerospace equipment. Excludes environmental control unit, personnel, self-contained.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
51
LVL_A:
F
LVL_B:
F
LVL_C:
F
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
50
PKG:
ZZZ0
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
001
THK:
X
TOS:
B
UCL:
A

Packaging Codes Definitions:

LVL A Code (LVL_A) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Type of Storage (TOS) B

Unheated general purpose.

Method of Preservation (MOP) 50

Watervaporproof protection with desiccant.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
114126
NMF Description:
Air Cooler/air Conditioners
UFC:
30740
LTL:
Rating variable
LCL:
--
WCC:
72E
TCC:
Z
SHC:
9
ADC:
A
ACC:
2

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72E

Engineer and material handling equipment, test/tool sets and equipment.

Air Commodity (ACC) 2

Arms/weapons (all types including inert component parts). when a 2" is indicated in the first position, then the special handlin.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide