Operating temperature range for heating is negative 50 degress farhenhiet to 80 degrees farhenhiet, temperature range for cooling is zero degrees farhenhiet to 130 degrees farhenhiet

Description

Environmental Control Unit NSN 4120-01-569-5238.

pdf NSN 4120-01-569-5238 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
30.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
20.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
30.000 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The value of the current flowing through the item when operated at its designed voltage,expressed in amperes.AFSS
Design Current Rating In Amps:
14.6
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
208.0 volts
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Hfc-134a
MRC:
The amount of refrigerant the item will hold.AWXK
Refrigerant Capacity:
4.0 ounces
MRC:
A relative measurement of the mass of an item with respect to its density.AZQK
Weight:
290.000 pounds
MRC:
The capacity of the item to cool,expressed in british thermal units per hour.CYJE
Cooling Capacity In Btu Per Hour:
24000.0
MRC:
The capacity of the item to heat,expressed in british thermal units per hour.CYKM
Heating Capacity In Btu Per Hour:
13400.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
--
NIIN:
015695238
MRC:
--
NATO Stock Number:
4120-01-569-5238
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A505G0
MRC:
--
INC:
06486
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4120-01-569-5238

A self-contained unit designed to perform the functions of cooling, circulating, filtering, dehumidifying or otherwise processing of air. It may also be equipped to perform the additional functions of heating or humidifying. It may be the air cycle type used in aircraft or the vapor cycle type applicable to ground or aerospace equipment. Excludes environmental control unit, personnel, self-contained.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
00
MOP:
10
PKG:
69Z0
PRES MAT:
00
WRAP MAT:
00
ICQ:
AAA
THK:
0
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 10

Physical protection.

Cushion Material (CUSH) 00

No requirement.

Preservation Material (PRES_MAT) 00

No requirement.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
114125
NMF Description:
Air Cooler/conditioner/heat Pump
UFC:
58510
LTL:
Rating variable
LCL:
--
WCC:
659
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 659

Electrical appliances, large.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide