4120-01-612-5212

Air Conditioner email this page

Model or part number: 42BVE40R

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Environmental Control Unit NSN 4120-01-612-5212.

pdf NSN 4120-01-612-5212 Datasheet

MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The value of the current flowing through the item when operated at its designed voltage,expressed in amperes.AFSS
Design Current Rating In Amps:
2.0
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Heating and cooling
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
460.0 volts
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
1.5
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Water
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The number of electric motors provided.AWLX
Electric Motor Quantity:
1
MRC:
Indicates the type of cooling for which the condenser is designed.AZAD
Condenser Cooling Type:
Water
MRC:
Indicates the type of compressor unit for which the item is designed.AZSD
Compressor Unit Type:
Hermetically sealed
MRC:
An indication of the rated kilowatt of the item.CTMG
Kilowatt Rating:
1.397
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Fan coil unit
MRC:
The capacity of the item to cool,expressed in british thermal units per hour.CYJE
Cooling Capacity In Btu Per Hour:
125225.611
MRC:
The capacity of the item to heat,expressed in british thermal units per hour.CYKM
Heating Capacity In Btu Per Hour:
10236.426
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
--
NIIN:
016125212
MRC:
--
NATO Stock Number:
4120-01-612-5212
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A505G0
MRC:
--
INC:
06486
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4120-01-612-5212

A self-contained unit designed to perform the functions of cooling, circulating, filtering, dehumidifying or otherwise processing of air. It may also be equipped to perform the additional functions of heating or humidifying. It may be the air cycle type used in aircraft or the vapor cycle type applicable to ground or aerospace equipment. Excludes environmental control unit, personnel, self-contained.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
00
MOP:
10
PKG:
PRES MAT:
00
WRAP MAT:
00
ICQ:
AAA
THK:
0
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 10

Physical protection.

Cushion Material (CUSH) 00

No requirement.

Preservation Material (PRES_MAT) 00

No requirement.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
114125
NMF Description:
Air Cooler/conditioner/heat Pump
UFC:
58510
LTL:
Rating variable
LCL:
--
WCC:
659
TCC:
Z
SHC:
9
ADC:
A
ACC:
V

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 659

Electrical appliances, large.

Air Commodity (ACC) V

Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide