4130-00-152-1292

Refrigerating Water Chiller email this page

Model or part number: C2C0214R2

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Manufacturers name water chiller, height 30 in., operating voltage 208/220vac 3 phase, 60 cycles, with safety cut off switch, model rrl4-0175-tfc, t.O. 40r3-5-3-1

pdf NSN 4130-00-152-1292 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
28.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
22.375 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 22
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
The element,compound,or mixture of which the shell is fabricated.AEUG
Shell Material:
Aluminum
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh
MRC:
Indicates the operating location of the refrigerant.AWCK
Refrigerant Operating Location:
In tubes
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Coiled
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Steel, corrosion resisting
MRC:
The number of water connections provided.AWKT
Water Connection Quantity:
2
MRC:
Indicates the type of water connection/s/.AWKW
Water Connection Type:
Threaded pipe
MRC:
The number of refrigerant inlet connections provided.AWKX
Refrigerant Inlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant inlet connection/s/.AWKY
Refrigerant Inlet Connection Type:
Flare tube
MRC:
Designates the size of the water connection.AWKZ
Water Connection Size:
1/2 in o.D.
MRC:
Designates the size of the refrigerant inlet connection.AWLA
Refrigerant Inlet Connection Size:
1/2 in o.D.
MRC:
The number of refrigerant outlet connections provided.AWLB
Refrigerant Outlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant outlet connection/s/.AWLC
Refrigerant Outlet Connection Type:
Flare tube
MRC:
Designates the size of the refrigerant outlet connection.AWLD
Refrigerant Outlet Connection Size:
1/2 in o.D.
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWH
Water Side Test Minimum Pressure:
35.0 pounds per square inch
MRC:
--
NIIN:
001521292
MRC:
--
NATO Stock Number:
4130-00-152-1292
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T240-A
MRC:
--
INC:
13452
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4130-00-152-1292

An item of equipment, whose main elements are an arrangement of tubes within a shell, through which the flow of water and refrigerant is maintained in such a heat transfer relationship that the water is chilled. Excludes chilled water unit, bakery.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
36.0 X 25.0 X 33.5
Paclk Weight:
322.0000lbs
Item Weight:
0.0000lbs
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
AD
MOP:
10
PKG:
PRES MAT:
00
WRAP MAT:
00
ICQ:
000
THK:
X
TOS:
UCL:
B

Packaging Codes Definitions:

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 10

Physical protection.

Cushion Material (CUSH) AD

Cushion, anchor, block or brace as required.

Preservation Material (PRES_MAT) 00

No requirement.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
053220
NMF Description:
Water Coolers/freeze Apparatus Comb
UFC:
30720
LTL:
85.0
LCL:
85.0
WCC:
72E
TCC:
Z
SHC:
Z
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72E

Engineer and material handling equipment, test/tool sets and equipment.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) Z

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide