4130-00-831-2194

Refrigerating Water Chiller email this page

Model or part number: D1895

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

pdf NSN 4130-00-831-2194 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
93.152 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant 12
MRC:
The installed position for which the item is designed.ADSM
Mounting Position:
Horizontal
MRC:
The element,compound,or mixture of which the shell is fabricated.AEUG
Shell Material:
Brass
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh
MRC:
Indicates the operating location of the refrigerant.AWCK
Refrigerant Operating Location:
In tubes
MRC:
The amount of effective cooling area.AWGF
Effective Cooling Area:
300.000 square feet
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Straight
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
A measurement of the longest dimension of the shell,in distinction from width.AWKR
Shell Length:
6.927 feet
MRC:
The length of a straight line which passes through the center of the shell,and terminates at the outside circumference.AWKS
Shell Outside Diameter:
16.000 inches
MRC:
The number of water connections provided.AWKT
Water Connection Quantity:
2
MRC:
Indicates the type of water connection/s/.AWKW
Water Connection Type:
Flange
MRC:
The number of refrigerant inlet connections provided.AWKX
Refrigerant Inlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant inlet connection/s/.AWKY
Refrigerant Inlet Connection Type:
Tube
MRC:
Designates the size of the water connection.AWKZ
Water Connection Size:
4 in. Ips
MRC:
Designates the size of the refrigerant inlet connection.AWLA
Refrigerant Inlet Connection Size:
4-1/8 in od
MRC:
The number of refrigerant outlet connections provided.AWLB
Refrigerant Outlet Connection Quantity:
1
MRC:
Indicates the type of refrigerant outlet connection/s/.AWLC
Refrigerant Outlet Connection Type:
Tube
MRC:
Designates the size of the refrigerant outlet connection.AWLD
Refrigerant Outlet Connection Size:
1-5/8 in od
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWG
Refrigerant Side Test Minimum Pressure:
250.0 pounds per square inch
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWH
Water Side Test Minimum Pressure:
225.0 pounds per square inch
MRC:
--
NIIN:
008312194
MRC:
--
NATO Stock Number:
4130-00-831-2194
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T240-A
MRC:
--
INC:
13452
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4130-00-831-2194

An item of equipment, whose main elements are an arrangement of tubes within a shell, through which the flow of water and refrigerant is maintained in such a heat transfer relationship that the water is chilled. Excludes chilled water unit, bakery.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
053100
NMF Description:
Cooling R Freezing Boxes R Refrig
UFC:
30650
LTL:
92.5
LCL:
92.5
WCC:
752
TCC:
Z
SHC:
9
ADC:
A
ACC:
S

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 752

Prefabricated structures & scaffolding.

Air Commodity (ACC) S

Office and school supplies and equipment including office machines, furniture and stationary..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide