4130-01-228-1301

Air Cooler Unit email this page

Model or part number: H-4 LVR-2.0KW

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Mil-a-24775; reversible connections (lh/rh); high impact shock & vibration resistance; has lvr (low voltage release) capability

Description

Variable Air Volume Terminal Unit NSN 4130-01-228-1301.

pdf NSN 4130-01-228-1301 Datasheet

MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
14.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
52.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
36.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac heater
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Chilled water
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel, galvanized
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1800.0
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Fan coil unit
MRC:
The rated horsepower of the prime mover.AHZX
Prime Mover Horsepower Rating:
0.500
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
The number of tubes provided in the coil.AWLQ
Coil Tube Quantity:
1
MRC:
The number of tube circuits provided.AWLR
Tube Circuit Quantity:
24
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange union
MRC:
Designates the size of the supply connection.AWLT
Supply Connection Size:
625 in. Od
MRC:
Designates the size of the return connection.AWLW
Return Connection Size:
625 in. Od
MRC:
An indication of whether or not a case with a built-in condensate drain pan is included.AWLZ
Case With Built-in Condensate Drain Pan:
Included
MRC:
Indicates the type of fan provided.AWMA
Fan Type:
Centrifugal
MRC:
Indicates the type of drive provided for the fan.AWMB
Fan Drive Type:
Direct
MRC:
The nominal capacity of the item to cool or heat,expressed in british thermal units per hour.CWMP
Capacity In Btu Per Hour:
22890.0 cooling and 22890.0 heating
MRC:
The rated power the heater can safely consume or provide,measured in kilowatts.CWMQ
Heater Wattage Rating In Kilowatts:
2.0
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0 heater
MRC:
The number of alternating current phases.FAAZ
Phase:
Three heater
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 fan motor
MRC:
--
NIIN:
012281301
MRC:
--
NATO Stock Number:
4130-01-228-1301
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
MRC:
N/A
MIL-STD
FIIG:
--
FIIG:
T240-C
MRC:
--
INC:
11361
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4130-01-228-1301

A unit comprising a fin and tube heat transfer element, filters and may or may not have a motor driven fan, inclosed in a casing for the purpose of cooling and removing moisture from the air in a space where the unit is installed. It may include electric heater and/or electrostatic precipitator. Excludes units containing compressor, condenser and means for introducing air from outside sources.

Recent Solicitations Most recent solicitations for NSN 4130-01-228-1301

End Date
Solicitation
Qty
Purchase Request
End Date:
2022-07-11
Solicitation:
SPE8E822T3259
Qty:
3
Purchase Request:
0094925846
End Date:
2021-12-27
Solicitation:
SPE8E822T0800
Qty:
1
Purchase Request:
0092427462
End Date:
2021-03-15
Solicitation:
SPE8E821T2167
Qty:
1
Purchase Request:
0088504894
End Date:
2017-12-11
Solicitation:
SPE8E818T1156
Qty:
6
Purchase Request:
0071724092
End Date:
2017-06-22
Solicitation:
SPE8EB17T2377
Qty:
2
Purchase Request:
0069394220
End Date:
2017-10-12
Solicitation:
SPE8E818T0001
Qty:
2
Purchase Request:
0071077590

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
540.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
AD
MOP:
10
PKG:
68ZZ
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 10

Physical protection.

Cushion Material (CUSH) AD

Cushion, anchor, block or brace as required.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
053100
NMF Description:
Cooling R Freezing Boxes R Refrig
UFC:
30650
LTL:
92.5
LCL:
--
WCC:
659
TCC:
Z
SHC:
9
ADC:
A
ACC:
E

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 659

Electrical appliances, large.

Air Commodity (ACC) E

Engineer supplies, other than those listed under code b..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

DLA History / Forecast Quantities

Construction & Equipment Supply Chain
01/1807/1805/1902/20
2.002.002.002.00

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide