Variable Air Volume Terminal Unit NSN 4130-01-250-1956.

pdf NSN 4130-01-250-1956 Datasheet

MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
15.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
14.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
81.375 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac fan motor
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flare tube and pipe
MRC:
Designates the size of the supply connection.AWLT
Supply Connection Size:
1/2 in. Sae
MRC:
Designates the size of the return connection.AWLW
Return Connection Size:
7/8 in. Od
MRC:
An indication of whether or not a case with a built-in condensate drain pan is included.AWLZ
Case With Built-in Condensate Drain Pan:
Included
MRC:
Indicates the type of fan provided.AWMA
Fan Type:
Axial
MRC:
Indicates the type of drive provided for the fan.AWMB
Fan Drive Type:
Direct
MRC:
The nominal capacity of the item to cool or heat,expressed in british thermal units per hour.CWMP
Capacity In Btu Per Hour:
16400.0 cooling
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
220.0 fan motor
MRC:
The number of alternating current phases.FAAZ
Phase:
Single fan motor
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 fan motor
MRC:
--
NIIN:
012501956
MRC:
--
NATO Stock Number:
4130-01-250-1956
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T240-C
MRC:
--
INC:
11361
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4130-01-250-1956

A unit comprising a fin and tube heat transfer element, filters and may or may not have a motor driven fan, inclosed in a casing for the purpose of cooling and removing moisture from the air in a space where the unit is installed. It may include electric heater and/or electrostatic precipitator. Excludes units containing compressor, condenser and means for introducing air from outside sources.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
H
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
10
PKG:
18ZZ
PRES MAT:
00
WRAP MAT:
XX
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) H

Packing shall be accomplished using boxes fabricated in accordance with astm-d5118, class weather-resistant.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 10

Physical protection.

Preservation Material (PRES_MAT) 00

No requirement.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
114125
NMF Description:
Air Cooler/conditioner/heat Pump
UFC:
58510
LTL:
Rating variable
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
V

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) V

Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide