4130-01-311-3307

Refrigeration Condenser email this page

Model or part number: 376-26624F

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Water Cooled Refrigerating Condenser NSN 4130-01-311-3307.

pdf NSN 4130-01-311-3307 Datasheet

MRC:
The refrigeration capacity of the item as rated by industry,expressed in tons per hour.AAYE
Refrigeration Flow Rate In Tons Per Hour:
200.000
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water
MRC:
The element,compound,or mixture of which the head is fabricated,excluding any surface treatment.ARGE
Head Material:
Nickel and aluminum and bronze
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
294
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh or salt
MRC:
The number of passes provided.AWGE
Pass Quantity:
2
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper nickel alloy
MRC:
A measurement of the longest dimension of a tube between the inside faces of the tube sheets,in distinction from width.AWGK
Tube Effective Length:
146.500 feet
MRC:
An indication of whether of not the tube(s) is provided with fins.AWGL
Tube Fin:
Provided
MRC:
A measurement of the longest dimension of the shell,in distinction from width.AWKR
Shell Length:
144.000 inches
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWG
Refrigerant Side Test Minimum Pressure:
50.0 pounds per square inch
MRC:
Indicates the type of cooling.AYTS
Cooling Type:
Water
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Condenser x chiller rfg
MRC:
--
NIIN:
013113307
MRC:
--
NATO Stock Number:
4130-01-311-3307
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T240-A
MRC:
--
INC:
36880
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4130-01-311-3307

A self-contained heat transfer device which receives high pressure gas at temperatures above that of the cooling medium, to which the device passes latent heat from the refrigerant gas, thereby causing it to liquefy.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
A
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
Q
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
ZZZZ
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
000
THK:
Z
TOS:
A
UCL:
O

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) A

Packaging is in accordance with a procedural specification or a special packaging instruction (spi). the appropriate specification number will be shown in the clear in the supplemental data area.

Type of Storage (TOS) A

Heated general purpose - heated 40 f and above.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
123410
NMF Description:
Evaporator Refrigerator
UFC:
62780
LTL:
150.0
LCL:
Rating variable
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide