Variable Air Volume Terminal Unit NSN 4130-01-311-3308.

pdf NSN 4130-01-311-3308 Datasheet

MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
54.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
76.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac fan motor
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Water
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel, galvanized
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded pipe
MRC:
Designates the size of the supply connection.AWLT
Supply Connection Size:
2.5in
MRC:
Designates the size of the return connection.AWLW
Return Connection Size:
2.5in
MRC:
An indication of whether or not a case with a built-in condensate drain pan is included.AWLZ
Case With Built-in Condensate Drain Pan:
Included
MRC:
The nominal capacity of the item to cool or heat,expressed in british thermal units per hour.CWMP
Capacity In Btu Per Hour:
265259.0 cooling
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0 fan motor and 460.0 fan motor
MRC:
The number of alternating current phases.FAAZ
Phase:
Three fan motor
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 fan motor
MRC:
--
NIIN:
013113308
MRC:
--
NATO Stock Number:
4130-01-311-3308
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T240-C
MRC:
--
INC:
11361
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4130-01-311-3308

A unit comprising a fin and tube heat transfer element, filters and may or may not have a motor driven fan, inclosed in a casing for the purpose of cooling and removing moisture from the air in a space where the unit is installed. It may include electric heater and/or electrostatic precipitator. Excludes units containing compressor, condenser and means for introducing air from outside sources.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
114.0 X 72.0 X 54.0
Paclk Weight:
2,012.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
F
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
LK
MOP:
10
PKG:
ZZZZ
PRES MAT:
00
WRAP MAT:
00
ICQ:
000
THK:
0
TOS:
B
UCL:
A

Packaging Codes Definitions:

LVL A Code (LVL_A) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Type of Storage (TOS) B

Unheated general purpose.

Method of Preservation (MOP) 10

Physical protection.

Cushion Material (CUSH) LK

Wood blocking and bracing, fasteners, or steel strapping, for tie-down purposes. rubber tired wheels shall be blocked clear of the floor of the crate or skid and shall not be load bearing.

Preservation Material (PRES_MAT) 00

No requirement.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
123410
NMF Description:
Evaporator Refrigerator
UFC:
62780
LTL:
150.0
LCL:
Rating variable
WCC:
658
TCC:
Z
SHC:
R
ADC:
Z
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) Z

Shipment is not a consolidation, but does exceed 84 inches in one or more dimensions.

Air Special Handling (SHC) R

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »