Description

Portable Fire Pump NSN 4320-00-059-2392.

pdf NSN 4320-00-059-2392 Datasheet

MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Round flange
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Round flange
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Watertight
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Blower cooled
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
650.0 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
229.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3500.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
65.0
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated without repair parts
MRC:
--
NIIN:
000592392
MRC:
--
NATO Stock Number:
4320-00-059-2392
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A19400
MRC:
--
INC:
17988
MRC:
--
IMM:
AX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4320-00-059-2392

An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
Q
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
ZZZZ
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
A
UCL:
O

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Type of Storage (TOS) A

Heated general purpose - heated 40 f and above.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8413919520
NAICS:
333911
End Use Class:
21100
SITC:
74291
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8413919520

Parts, Nesoi, Of Pumps For Liquids

End Use Code 21100

Industrial Engines

Standard Intl. Trade Class (SITC) 74291

Parts Of Pumps For Liquids

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
128000
NMF Description:
Pumps Pwr Noi/working Heads/parts
UFC:
64870
LTL:
85.0
LCL:
85.0
WCC:
594
TCC:
Z
SHC:
9
ADC:
A
ACC:
V

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 594

Pumps and parts, (machinery and parts),(less than 35 feet).

Air Commodity (ACC) V

Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide