4320-00-451-3029

Centrifugal Pump Unit email this page

Model or part number: AB294-0541-000

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Portable Fire Pump NSN 4320-00-451-3029.

pdf NSN 4320-00-451-3029 Datasheet

MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Round flange
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Round flange
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydrocarbon fuels and oils
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Self ventilated
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
1100.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
150.0 pounds per square inch gage
MRC:
The vertical distance from the level of supply to the center of the pump.AHYY
Suction Lift:
20.000 feet
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Double
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-priming
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
150.000 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
--
NIIN:
004513029
MRC:
--
NATO Stock Number:
4320-00-451-3029
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A19400
MRC:
--
INC:
17988
MRC:
--
IMM:
AX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4320-00-451-3029

An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
A
SPI No.:
SPI Rev.:
SPC Mkg:
24
LVL_A:
F
LVL_B:
F
LVL_C:
F
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
ZZZZ
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
000
THK:
Z
TOS:
Y
UCL:
A

Packaging Codes Definitions:

LVL A Code (LVL_A) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) A

Packaging is in accordance with a procedural specification or a special packaging instruction (spi). the appropriate specification number will be shown in the clear in the supplemental data area.

Special Markings Code (SPC_MKG) 24

Open for inspection or use only.

Type of Storage (TOS) Y

Ammunition (class v; igloos and magazines).

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8413919520
NAICS:
333911
End Use Class:
21100
SITC:
74291
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8413919520

Parts, Nesoi, Of Pumps For Liquids

End Use Code 21100

Industrial Engines

Standard Intl. Trade Class (SITC) 74291

Parts Of Pumps For Liquids

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
128000
NMF Description:
Pumps Pwr Noi/working Heads/parts
UFC:
64870
LTL:
85.0
LCL:
85.0
WCC:
594
TCC:
Z
SHC:
9
ADC:
A
ACC:
V

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 594

Pumps and parts, (machinery and parts),(less than 35 feet).

Air Commodity (ACC) V

Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide