Submit this form for current pricing and availability of this NSN.
Description
Portable Fire Pump NSN 4320-01-155-8984.
NSN 4320-01-155-8984 Datasheet
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded internal
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Blower cooled
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
2.0058 cubic feet
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Used on 82 ft coast guard vessels
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
33.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
12.1 pounds per square inch gage
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
28.000 feet
MRC:
The vertical distance from the level of supply to the center of the pump.AHYY
Suction Lift:
25.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3450.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
40.0 and 20.0
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
1.000-11-1/2 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
1.250-11-1/2 npt
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
0.5 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0 and 460.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
--
NIIN:
011558984
MRC:
--
NATO Stock Number:
4320-01-155-8984
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A19400
MRC:
--
INC:
17988
MRC:
--
IMM:
AX
All Products Certified
Factory New, New Material, New Surplus, Overhauled, Serviceable,
Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance,
and any other documents/trace when applicable. We have a 7 year record retention.
Quality | ISO 9001:2015 + AS9120B
We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC,
ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.
Government issue definition of NSN 4320-01-155-8984
An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.
Import / Export
Schedule B Classification
Schedule B Number
NAICNational Association of Insurance Commissioners
End UseA classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITCCommodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8413919520
NAICS:
333911
End Use Class:
21100
SITC:
74291
USDA:
1
HITECH:
0
Schedule B Codes Definitions:
Schedule B 8413919520
Parts, Nesoi, Of Pumps For Liquids
End Use Code 21100
Industrial Engines
Standard Intl. Trade Class (SITC) 74291
Parts Of Pumps For Liquids
Manufacturers