4520-01-042-0409

Electric Water Heater email this page

Model or part number: S-15-208V60CY-3PH

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Air-gas Circulation Heater NSN 4520-01-042-0409.

pdf NSN 4520-01-042-0409 Datasheet

MRC:
The maximum pressure at which an item is designed to operate.AAJJ
Maximum Operating Pressure:
300.0 pounds
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Enameled
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the inside surface.AAJQ
Inside Surface Treatment:
Galvanized
MRC:
Indicates the type of heating unit which imparts heat.ABAL
Heating Element Type:
Any acceptable
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
23.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
32.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
22.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Single throw
MRC:
An indication of whether or not an insulated feature is included.AHGR
Insulated Feature:
Included
MRC:
An indication of whether or not an attachment device is included.ALHG
Attachment Device:
Not included
MRC:
The rated heating capacity of the item per hour.AMHR
Heating Capacity Per Hour:
154.0 gallons
MRC:
The number of degrees the temperature rises per hour.AMHX
Tempurature Rise Per Hour:
40.0 degrees fahrenheit
MRC:
An indication of whether or not a thermostatic switch is included.AMJX
Thermostatic Switch:
Included
MRC:
Indicates the capacity of the tank.AMKA
Tank Capacity:
16.0 gallons
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water inlet connection.AMLL
Water Inlet Connection Thread Size And Series/type Designator:
3/4-14 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the water outlet connection.AMLM
Water Outlet Connection Thread Size And Series/type Designator:
3/4-14 npt
MRC:
The number of water inlet connections.AMLQ
Water Inlet Connection Quantity:
1
MRC:
The number of water outlet connections.AMLR
Water Outlet Connection Quantity:
1
MRC:
The rated power which a heating element can safely consume or provide,measured in watts.AMRK
Heating Element Wattage Rating:
15000.000 single
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
208.0 ac
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
208.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single/three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
--
NIIN:
010420409
MRC:
--
NATO Stock Number:
4520-01-042-0409
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T285-A
MRC:
--
INC:
07180
MRC:
--
IMM:
AX KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4520-01-042-0409

A unit specifically designed for heating water by a direct fired method, utilizing electric heating element(s).

Recent Solicitations Most recent solicitations for NSN 4520-01-042-0409

End Date
Solicitation
Qty
Purchase Request
End Date:
2023-09-05
Solicitation:
SPE8E823T4821
Qty:
1
Purchase Request:
7004182791
End Date:
2022-08-29
Solicitation:
SPE8E822T3905
Qty:
1
Purchase Request:
0095484905

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
35.0 X 28.0 X 25.0
Paclk Weight:
176.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
F
LVL_B:
F
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
AD
MOP:
AE
PKG:
16ZZ
PRES MAT:
00
WRAP MAT:
00
ICQ:
000
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) AE

Seal or plug all openings and preserve by method 10.

Cushion Material (CUSH) AD

Cushion, anchor, block or brace as required.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8516100040
NAICS:
335228
End Use Class:
41030
SITC:
77581
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8516100040

Electric Storage Water Heaters

End Use Code 41030

Household Appliances

Standard Intl. Trade Class (SITC) 77581

Electric Instantaneous Or Storage Water Heaters and Immersion Heaters

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
026520
NMF Description:
Heaters Water
UFC:
12650
LTL:
Rating variable
LCL:
--
WCC:
72E
TCC:
Z
SHC:
9
ADC:
A
ACC:
B

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72E

Engineer and material handling equipment, test/tool sets and equipment.

Air Commodity (ACC) B

Construction materials: includes paint and related materials, prefabricated building, wood products, metal and composition mater.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide