4630-01-468-9180

Sewage Pumping Unit email this page

Model or part number: N12TA00001

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Approx. 100 gal. Capacity; unit will grind and pump 100 gal. In about 220 sec.; fitted with a check valve to srop back feed of the system; includes tank heater; dwg is aar-atics inc. Print no. 50384288

Description

Sump Pump Tank Unit NSN 4630-01-468-9180.

pdf NSN 4630-01-468-9180 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
42.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
25.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
36.000 inches
MRC:
The amount of current for which the item is designed.ARAG
Current Rating:
4.000 amperes
MRC:
The rated power that an item can safely consume or provide.BDWW
Wattage Rating:
150.000 watts
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
230.0 ac
MRC:
--
NIIN:
014689180
MRC:
--
NATO Stock Number:
4630-01-468-9180
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A23900
MRC:
--
INC:
08397
MRC:
--
IMM:
KZ
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4630-01-468-9180

An assembled unit consisting of one or more pumps internally contained in a receiver tank and powered by electric motor(s) externally mounted on cover plate of tank and automatically controlled. It is designed to handle drainage, flood water, effluent, raw sewage, or solids.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
Q
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
10
PKG:
ZZZ0
PRES MAT:
00
WRAP MAT:
XX
ICQ:
AAA
THK:
X
TOS:
A
UCL:
O

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Type of Storage (TOS) A

Heated general purpose - heated 40 f and above.

Method of Preservation (MOP) 10

Physical protection.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8413810040
NAICS:
333911
End Use Class:
21100
SITC:
74271
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8413810040

Pumps For Liquids, Nesoi

End Use Code 21100

Industrial Engines

Standard Intl. Trade Class (SITC) 74271

Pumps For Liquids, N.e.s.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
128000
NMF Description:
Pumps Pwr Noi/working Heads/parts
UFC:
64870
LTL:
85.0
LCL:
--
WCC:
594
TCC:
Z
SHC:
9
ADC:
A
ACC:
V

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 594

Pumps and parts, (machinery and parts),(less than 35 feet).

Air Commodity (ACC) V

Trailers, vehicles, machinery, shop and warehouse equipment and supplies including special tools and equipment, ground servicing.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide