4730-00-033-5808

Steam Trap email this page

Model or part number: 400-485-1 1-4

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Thermostatic Trap NSN 4730-00-033-5808.

pdf NSN 4730-00-033-5808 Datasheet

MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.AJYP
Screw Thread Series Designator:
Npt
MRC:
The design of the body of the item.ALCS
Body Design:
Angle pattern
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Bronze body
MRC:
Indicates the design type of the item.APGF
Design Type:
Thermostatic
MRC:
The maximum steam pressure at which the item is designed to operate.AXSW
Maximum Steam Working Pressure:
100.0 pounds per square inch
MRC:
An indication of whether or not a strainer is included.BMBL
Strainer:
Not included
MRC:
The rated capacity of the item at maximum working pressure.BZSX
Rated Capacity At Maximum Working Pressure:
6200.000 pounds of water per hour
MRC:
An indication of whether or not the inlet and/or outlet connection(s) is identical.BZTB
Inlet/outlet Connection Similarity:
Identical
MRC:
The value used to define the nominal diameter of the inlet and/or outlet connection pipe.BZTC
Inlet/outlet Connection Pipe Size:
1.250 inches
MRC:
Indicates the type of inlet and/or outlet connection provided.BZTD
Inlet/outlet Connection Type:
Female iron pipe
MRC:
An indication of whether or not the inlet and/or outlet connection is threaded.BZTH
Inlet/outlet Connection Thread Provision:
Threaded
MRC:
Indicates the location of the inlet in relation to the installed position of the item.BZTJ
Inlet Location In Relation To Installed Position:
Lower side
MRC:
Indicates the location of the outlet in relation to the installed position of the item.BZTK
Outlet Location In Relation To Installed Position:
Bottom end
MRC:
An indication of whether or not a gage glass is included.BZTL
Gage Glass:
Not included
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Any acceptable
MRC:
--
NIIN:
000335808
MRC:
--
NATO Stock Number:
4730-00-033-5808
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T359-B
MRC:
--
INC:
04853
MRC:
--
IMM:
AX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 4730-00-033-5808

A device for allowing the passage of condensate, or of air and condensate, and for preventing the passage of steam.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
H
LVL_C:
U
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
BL
PKG:
18ZZ
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) H

Packing shall be accomplished using boxes fabricated in accordance with astm-d5118, class weather-resistant.

LVL C Code (LVL_C) U

Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) postal regulations, (b) department of transportation regulations, (c) civil air regulations, (d) uniform freight classification rules, (e) national motor freight classification rules, (f) american truckers' association rules, (g) other applicable carriers' rules, (h) military air regulations for dangerous materials. consolidation of shipments. all exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. dangerous goods shall be prepared for shipment according to applicable department of transportation (dot) regulations and international regulations in effect at time of shipment. shipment by parcel post must comply with postal regulations.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Method of Preservation (MOP) BL

Plug or seal all openings and preserve using method 20.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8402900090
NAICS:
332410
End Use Class:
21180
SITC:
71191
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8402900090

Heated Water Boilers, Except Heat Exchangers Parts For Steam Or Other Vapor Generating Boilers and Super

End Use Code 21180

Industrial Machines, Other

Standard Intl. Trade Class (SITC) 71191

Parts For Steam Generating Or Other Vapor Generating Boilers

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
130430
NMF Description:
Machinery:steam Traps
UFC:
65960
LTL:
85.0
LCL:
--
WCC:
736
TCC:
Z
SHC:
9
ADC:
A
ACC:
B

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 736

Plumbing supplies.

Air Commodity (ACC) B

Construction materials: includes paint and related materials, prefabricated building, wood products, metal and composition mater.

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide