5895-01-204-9748

Radio Frequency Monitor email this page
ITAR Registered

Images

Reference images of this national stock number
Reference of NSN 5895-01-204-9748

Model or part number: 105322

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Microprocessor controlled; fail safe operation; non-volatile memory; continuous automatic self test; interface for remote data acquisition; self diagnostics and fault isolation capability

Description

Power Monitor NSN 5895-01-204-9748.

pdf NSN 5895-01-204-9748 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.719 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.000 inches
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Vortac
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
10.0 1st voltage and 17.5 2nd voltage
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Monitor integration of tacan system parameters (decoding integrity and r/t power integrity)
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Fixed installation; rack mtd
MRC:
--
NIIN:
012049748
MRC:
--
NATO Stock Number:
5895-01-204-9748
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
A32200
MRC:
--
INC:
00771
MRC:
--
IMM:
TX TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5895-01-204-9748

A receiver for reproducing radio frequency transmission without interfering with it. It is used for checking on the operation of a transmitter, having radio frequency output, with regard to quality, deviation from assigned bands, materials transmitted, etc. It may include remote indicators.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
25.8 X 24.3 X 14.0
Paclk Weight:
37.1000lbs
Item Weight:
26.0000lbs
Item Dim:
020501900088
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
A
SPI No.:
F012049748
SPI Rev.:
A
SPC Mkg:
39
LVL_A:
0
LVL_B:
F
LVL_C:
0
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
GX
PKG:
ZZZ0
PRES MAT:
00
WRAP MAT:
ZZ
ICQ:
000
THK:
Z
TOS:
UCL:
B

Packaging Codes Definitions:

LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) A

Packaging is in accordance with a procedural specification or a special packaging instruction (spi). the appropriate specification number will be shown in the clear in the supplemental data area.

Special Markings Code (SPC_MKG) 39

Esd sensitive electronic device requirements of mil-std-129 apply.

Method of Preservation (MOP) GX

Preserve by method 41 as follows: items subject to damage by electromagnetic and electrostatic field forces shall be initally wrapped in material conforming to mil-prf-81705, type iii, or bags conforming to mil-dtl-117, type ii, class h, style 2, or cushioned in material conforming to a-a-3129 or ppp-c-795, class 2 or ppp-c-1797, type ii, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to mil-dtl-117, type i, class f, style 1. reclosable cushioned pouches conforming to mil-dtl-81997, type i or ii, may be used in lieu of initial wrap or cushioning. lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. electrostatic discharge (esd) sensitive caution labels shall be applied in accordance with mil-std-129. connectors and plugs (power or data) shall be covered with conductive caps/plugs.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9030908040
NAICS:
334515
End Use Class:
21400
SITC:
87479
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 9030908040

Parts and Accessories Of Articles Of Schedule B Subheading 9030.40

End Use Code 21400

Telecommunications Equipment

Standard Intl. Trade Class (SITC) 87479

Parts and Accessories For Instruments and Apparatus (except Meters) Measuring Etc. Electrical Quanities and Devices Measuring Etc. Ionized Radiations

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
063035
NMF Description:
Sets Radio/tv And Related Articles
UFC:
35070
LTL:
125.0
LCL:
77.5
WCC:
72D
TCC:
3
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) 3

Electrostatic sensitive device (esd).

Water Commodity (WCC) 72D

Communications/electronics, other than sigint/ew or comsec repair parts and components.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide