5915-01-374-2942

Radio Frequency Interference Filter email this page
ITAR Registered

Images

Reference images of this national stock number
Reference of NSN 5915-01-374-2942 Reference of NSN 5915-01-374-2942

Model or part number: STD210-1

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
55 functions

Description

Power Line Filter NSN 5915-01-374-2942.

pdf NSN 5915-01-374-2942 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 1.241 inches and 1.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 1.241 inches and 1.250 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
60.0 1st radio interference60.0 2nd radio interference60.0 3rd radio interference60.0 4th radio interference60.0 5th radio interference60.0 6th radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
5.0 1st radio interference5.0 2nd radio interference5.0 3rd radio interference5.0 4th radio interference5.0 5th radio interference5.0 6th radio interference
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference inductance-capacitance 2nd radio interference inductance-capacitance 3rd radio interference inductance-capacitance 4th radio interference inductance-capacitance 5th radio interference inductance-capacitance 6th radio interference
MRC:
The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
Maximum Tempurature Rise:
25.0 degrees celsius
MRC:
The specified points in the frequency spectrum at which insertion losses (as a function of frequency) under full load are measured,expressed in megahertz.AHCJ
Full Load Insertion Loss Frequencies In Megahertz:
10.0 and 100.0 and 1000.0 and 10000.0
MRC:
The least permissible values for attenuation of spurious or unwanted signals at designated points in the frequency spectrum,expressed in decibels.AHCK
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
7.0 and 35.0 and 72.0 and 72.0
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
66 terminal
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
66 pin input 1st function66 pin output 2nd function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
100.0 volts dc 1st radio interference 1st function100.0 volts dc 2nd radio interference 2nd function100.0 volts dc 3rd radio interference 3rd function100.0 volts dc 4th radio interference 4th function100.0 volts dc 5th radio interference 5th function100.0 volts dc 6th radio interference 6th function
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The maximum direct current voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CRDC
Maximum Dielectric Withstanding Dc Voltage:
250.0 volts at sea level
MRC:
The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
Body Surface Treatment:
Tin
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
C0ntact surfaces gold
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Filter connector
MRC:
--
NIIN:
013742942
MRC:
--
NATO Stock Number:
5915-01-374-2942
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
A047B0
MRC:
--
INC:
00765
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5915-01-374-2942

An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes filter, low pass and suppressor, ignition interference. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see filter, band suppression and filter, band pass. See also limiter, electrical noise.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
00
MOP:
41
PKG:
69F0
PRES MAT:
00
WRAP MAT:
EA
ICQ:
AAA
THK:
0
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 41

Watervaporproof bag, sealed.

Cushion Material (CUSH) 00

No requirement.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8527995030
NAICS:
334310
End Use Class:
41210
SITC:
76289
USDA:
1
HITECH:
4

Schedule B Codes Definitions:

Schedule B 8527995030

Reception Apparatus, Nesoi

End Use Code 41210

Stereo Equipment, Etc.

Standard Intl. Trade Class (SITC) 76289

Radiobroadcast Receivers, Not Combined With Sound Recording Or Reproducing Apparatus Nor With A Clock, Etc., N.e.s.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061990
NMF Description:
Electrical Equip:filters
UFC:
58500
LTL:
77.5
LCL:
--
WCC:
72D
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72D

Communications/electronics, other than sigint/ew or comsec repair parts and components.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide