5925-01-483-0111

Circuit Breaker email this page

Model or part number: IEG6-1REC4-61-15.0-21-V

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Vde approved; toggle handle color is red - marked with white letters of on/off and i/o; aproximate weight per pole 2.2 ounces; dielectric strength with auxiliary switched terminals 600 volts ac, 60 hertz

Description

Overload Switch NSN 5925-01-483-0111.

pdf NSN 5925-01-483-0111 Datasheet

MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.750 inches
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
1.530 inches
MRC:
A designation that describes the basic electrical configuration of a switch.AEGJ
Switch Contact Arrangement:
Single pole, double throw
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac all locations
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac all locations
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overcurrent all locations
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Magnetic-hydraulic all locations
MRC:
Indicates the type and voltage rating required to operate the auxiliary /remotely actuated/ trip actuator,expressed in volts.CPRK
Auxiliary Trip Coil Voltage Type And Rating In Volts:
125.0 ac all locations
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay all locations
MRC:
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
MRC:
The ultimate time per pole in which the device must trip,expressed in seconds.CPRP
Ultimate Trip Time Per Pole In Seconds:
0.700 all locations and 12.000 all locations
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
The function for which the auxiliary switch is designed and the number provided.CPRZ
Auxiliary Switch Function And Quantity:
1 control
MRC:
The basic internal electrical configuration of the trip mechanism.CPSM
Internal Trip Release Configuration:
Series/relay trip all locations
MRC:
The working period which the trip release is designed to operate.CQQC
Trip Release Duty Cycle:
Continuous all locations
MRC:
Indicates the location of the switch in relation to its designated position.CQSM
Switch Location And Position Designation:
Internal at pole one
MRC:
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
Trip Delay Time In Seconds Per Rated Continuous Current:
0.700 at 125 pct all locations and 12.000 at 125 pct all locations and 0.350 at 150 pct all locations and 7.000 at 150 pct all locations and 0.130 at 200 pct all locations and 3.000 at 200 pct all locations and 0.030 at 400 pct all locations and 1.000 at 400 pct all locations and 0.015 at 600 pct all locations and 0.300 at 600 pct all locations and 0.010 at 800 pct all locations and 0.150 at 800 pct all locations and 0.008 at 1000 pct all locations and 0.100 at 1000 pct all locations
MRC:
Indicates the type of protection for which the inclosure is designed.CQXF
Inclosure Protection Type For Which Designed:
Corrosion resistant and moisture resistant and salt water resistant and shock resistant and vibration resistant
MRC:
Indicates the type of terminal for providing electrical connection to the switch.CRTK
Switch Terminal Type:
Quick disconnect, male
MRC:
The amount of current,expressed in amperes,and the type for which the switch is rated.CSSX
Switch Current Rating And Type In Amps:
1.0 ac
MRC:
The voltage,expressed in volts,and current type for which the switch is rated.CSWP
Switch Voltage Rating And Type In Volts:
125.0 ac
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 all locations or 60.0 all locations
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw
MRC:
--
NIIN:
014830111
MRC:
--
NATO Stock Number:
5925-01-483-0111
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A030A0
MRC:
--
INC:
00136
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5925-01-483-0111

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8536200040
NAICS:
335313
End Use Class:
20005
SITC:
77252
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536200040

Automatic Circuit Breakers, For A Voltage Not Exceeding 1, 000 V, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77252

Automatic Circuit Breakers For A Voltage Not Exceeding 1, 000 Volts

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide