5925-01-649-4677

Circuit Breaker email this page

Images

Reference images of this national stock number
Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677 Reference of NSN 5925-01-649-4677

Model or part number: LELK121-1REC5-37275-50-G1-V

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Overload Switch NSN 5925-01-649-4677.

pdf NSN 5925-01-649-4677 Datasheet

MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Multipole-multiple actuator type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.490 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.515 inches
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
1.940 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.060 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Boat, riverine
MRC:
None.AJEC
Boss Height:
0.140 inches
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac and 240.0 ac all locations
MRC:
Indicates the type and voltage rating required to operate the auxiliary /remotely actuated/ trip actuator,expressed in volts.CPRK
Auxiliary Trip Coil Voltage Type And Rating In Volts:
120.0 ac all locations
MRC:
--
NIIN:
016494677
MRC:
--
NATO Stock Number:
5925-01-649-4677
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A030A0
MRC:
--
INC:
00136
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5925-01-649-4677

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8536200040
NAICS:
335313
End Use Class:
20005
SITC:
77252
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536200040

Automatic Circuit Breakers, For A Voltage Not Exceeding 1, 000 V, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77252

Automatic Circuit Breakers For A Voltage Not Exceeding 1, 000 Volts

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide