5930-00-884-9840

Thermostatic Switch email this page

Images

Reference images of this national stock number
Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840 Reference of NSN 5930-00-884-9840

Model or part number: 17102-0-150DEGF

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Not provided with visual indicating thermometer

Description

Thermal Switch NSN 5930-00-884-9840.

pdf NSN 5930-00-884-9840 Datasheet

MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.188 inches single threaded bushing
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.750 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.625 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.126 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
2.938 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.625 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Bulb
MRC:
The means of attaching the item.AXGY
Mounting Method:
Immersion well and threaded bushing
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Tubing end seal connection
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
14 single threaded bushing
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.500 inches single threaded bushing
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally closed, momentary action
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Wire lead
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
5.0 amperes resistive load first voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point adjustable, preset and actuation point adjustable, preset
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+100.00/+600.00 actuation point degrees fahrenheit and +100.00/+600.00 deactuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External deactuation point screw and external actuation point screw
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
3.00 differential point degrees fahrenheit and 600.00 actuation point degrees fahrenheit and 100.00 deactuation point degrees fahrenheit
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
230.0 ac at sea level first voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt single threaded bushing
MRC:
--
NIIN:
008849840
MRC:
--
NATO Stock Number:
5930-00-884-9840
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A048B0
MRC:
--
INC:
00451
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5930-00-884-9840

A switch that is actuated by changes in ambient temperature. Excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9032100000
NAICS:
334512
End Use Class:
21160
SITC:
87461
USDA:
1
HITECH:
6

Schedule B Codes Definitions:

Schedule B 9032100000

Thermostats

End Use Code 21160

Measuring, Testing, Control Instruments

Standard Intl. Trade Class (SITC) 87461

Thermostats

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
77.5
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide