5930-01-259-1323

Thermostatic Switch email this page

Images

Reference images of this national stock number
Reference of NSN 5930-01-259-1323 Reference of NSN 5930-01-259-1323

Model or part number: M1104095331

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Thermal Switch NSN 5930-01-259-1323.

pdf NSN 5930-01-259-1323 Datasheet

MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.628 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.572 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.385 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Disc
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between -80.0 degrees fahrenheit and 550.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, normally closed, momentary action
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab, solder lug
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
7.0 amperes resistive load second voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point adjustable, preset and deactuation point adjustable, preset
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
-5.00/+5.00 actuation point degrees fahrenheit
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
30.0 dc at sea level second voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Disc w/flange
MRC:
--
NIIN:
012591323
MRC:
--
NATO Stock Number:
5930-01-259-1323
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A048B0
MRC:
--
INC:
00451
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5930-01-259-1323

A switch that is actuated by changes in ambient temperature. Excludes circuit breaker; control, temperature (as modified); fuse (as modified); protector, thermal-overload, electrical motor; relay, thermal; and thermostat, flow control. See also control, temperature (as modified) and regulator, temperature (as modified).

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9032100000
NAICS:
334512
End Use Class:
21160
SITC:
87461
USDA:
1
HITECH:
6

Schedule B Codes Definitions:

Schedule B 9032100000

Thermostats

End Use Code 21160

Measuring, Testing, Control Instruments

Standard Intl. Trade Class (SITC) 87461

Thermostats

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide