5945-00-240-6007

Rotary Relay email this page

Model or part number: 20362

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

pdf NSN 5945-00-240-6007 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.313 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.563 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 6-32 tapped mtg holes on 15/16 in. By 1-5/8 in. Mtg centers
MRC:
The basic structure of the item.ALXF
Structural Design:
Nonpile-up
MRC:
The operating current for which the item is rated.APAM
Operating Current Rating:
0.220 amperes
MRC:
The value/s/ of direct current potential which must be applied to the item for operation,expressed in volts.APBR
Dc Operating Voltage Rating In Volts:
26.500
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Dc
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
10000.000
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
0.200 amperes resistive
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
0.200 amperes resistive
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
10000.000
MRC:
The specific number of contact terminals included.APNG
Contact Terminal Quantity:
3
MRC:
The specific number of coil terminals included.APNH
Coil Terminal Quantity:
2
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
0.400 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
200.000 milliamperes
MRC:
The direction of rotation for which the item is designed.AYSY
Rotation Direction For Which Designed:
Clockwise
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
120.000 ohms
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
Spdt, double break
MRC:
The number of coil winding(s) provided.CPWL
Coil Winding Quantity:
1
MRC:
An indication of the characteristic(s) of a winding.CPWM
Winding Characteristic:
Single wound untapped
MRC:
The amount of direct current resistance required to activate the coil pull-in.CPWP
Coil Pull-in Dc Resistance Rating:
15.000 ohms
MRC:
The amount of direct current resistance required to maintain operation of the coil hold-in.CPWQ
Coil Hold-in Dc Resistance Rating:
325.000 ohms
MRC:
The measurement of the shaft rotation,expressed in degrees.CPWT
Shaft Rotation In Deg:
20.000
MRC:
--
NIIN:
002406007
MRC:
--
NATO Stock Number:
5945-00-240-6007
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T142-S
MRC:
--
INC:
03890
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5945-00-240-6007

A relay whose contact arm may rotate through 360 degrees but not in one operation. Includes rotary relays which automatically reset. For an item having the dual functions of a switch and a relay assembled together on a common mounting, see relay-switch. Excludes switch, rotary; switch, stepping; and switch, telephone (as modified).

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Q
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
BG
MOP:
41
PKG:
69F0
PRES MAT:
00
WRAP MAT:
EA
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) 41

Watervaporproof bag, sealed.

Cushion Material (CUSH) BG

A-a-1898, grade ii, water resistant cellulose cushioning.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8536509065
NAICS:
335931
End Use Class:
20005
SITC:
77255
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536509065

Switches, For A Voltage Not Exceeding 1000 Volts, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77255

Switches For Electrical Apparatus, N.e.s., For Voltages Not Exceeding 1, 000 Volts

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
061300
NMF Description:
Circuit Breaker/switch Noi
UFC:
34410
LTL:
77.5
LCL:
--
WCC:
658
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 658

Electrical appliances, small.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide