About this product
Failure rate level 3.0 percent

Description

Time Delay Relay NSN 5945-01-141-2052.

pdf NSN 5945-01-141-2052 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.062 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.320 inches
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
44.0 ohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 plug-in terminal single mounting facility
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
2 pole, double throw, one position momentary
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
5.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
2.0 amperes dc resistive load and 125.0 milliamperes ac resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
115.0 ac and 28.0 dc
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-r-39016 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 pin all functions
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-r-39016/13 government specification
MRC:
--
NIIN:
011412052
MRC:
--
NATO Stock Number:
5945-01-141-2052
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A03300
MRC:
--
INC:
32512
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5945-01-141-2052

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8536490050
NAICS:
335314
End Use Class:
20005
SITC:
77254
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8536490050

Relays, Electromechanical, With Contacts Rated At Less Than 10 A, For A Voltage Exceeding 60 V But Not Exceeding 1000 V

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77254

Relays For Electrical Apparatus Used With Electrical Circuits Not Exceeding 1, 000 Volts

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide