Magpot NSN 5950-01-254-8495.

pdf NSN 5950-01-254-8495 Datasheet

MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.465 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.310 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.410 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
3.0 milliamperes dc single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 pin
MRC:
--
NIIN:
012548495
MRC:
--
NATO Stock Number:
5950-01-254-8495
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A058B0
MRC:
--
INC:
32496
MRC:
--
IMM:
TX CX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5950-01-254-8495

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1), pulse.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
1,500.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
39
LVL_A:
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
GX
PKG:
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 39

Esd sensitive electronic device requirements of mil-std-129 apply.

Method of Preservation (MOP) GX

Preserve by method 41 as follows: items subject to damage by electromagnetic and electrostatic field forces shall be initally wrapped in material conforming to mil-prf-81705, type iii, or bags conforming to mil-dtl-117, type ii, class h, style 2, or cushioned in material conforming to a-a-3129 or ppp-c-795, class 2 or ppp-c-1797, type ii, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to mil-dtl-117, type i, class f, style 1. reclosable cushioned pouches conforming to mil-dtl-81997, type i or ii, may be used in lieu of initial wrap or cushioning. lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. electrostatic discharge (esd) sensitive caution labels shall be applied in accordance with mil-std-129. connectors and plugs (power or data) shall be covered with conductive caps/plugs.

Manufacturers