5985-00-411-3437

Electrical Dummy Load email this page
ITAR Registered

Images

Reference images of this national stock number
Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437 Reference of NSN 5985-00-411-3437

Model or part number: 534122-1

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Description

Load Waveguide NSN 5985-00-411-3437.

pdf NSN 5985-00-411-3437 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 3.670 inches and 3.730 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.320 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 1.565 inches and 1.645 inches
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+9.000/+9.600 gigahertz
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.20
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
125.000 kilowatts peak and 125.000 watts average
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+9.000/+9.600 gigahertz
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Waveguide flange
MRC:
The alphabetical characters and numerals which identify the specific waveguide flange type.AKSA
Waveguide Flange Designation:
Ug135/u
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
The nominal exerted outward force,per unit of area,for which the item is designed.AWNC
Internal Operating Pressure:
19.0 pounds per square inch gage
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-cooled
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Waveguide mounted
MRC:
--
NIIN:
004113437
MRC:
--
NATO Stock Number:
5985-00-411-3437
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
A19800
MRC:
--
INC:
00335
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 5985-00-411-3437

A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also load bank, electrical.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
NA
MOP:
41
PKG:
69F0
PRES MAT:
00
WRAP MAT:
00
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 41

Watervaporproof bag, sealed.

Cushion Material (CUSH) NA

Ppp-c-795, cellular plastic film cushioning; or a-a-3129, open cell plastic cushioning; or ppp-c-1797, polypropylene foam cushioning; or a-a-59136, polyethylene foam cushioning.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9030330080
NAICS:
334515
End Use Class:
21160
SITC:
87475
USDA:
1
HITECH:
6

Schedule B Codes Definitions:

Schedule B 9030330080

Other Instruments and Apparatus For Measuring Or Checking Power, Without A Recording Device, Nesoi

End Use Code 21160

Measuring, Testing, Control Instruments

Standard Intl. Trade Class (SITC) 87475

Instruments and Apparatus, N.e.s. For Measuring Or Checking Voltage, Current, Resistance Or Power, Without A Recording Device

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
062920
NMF Description:
Regulators Induction/voltage
UFC:
35120
LTL:
Rating variable
LCL:
--
WCC:
723
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 723

Radio parts and equipment, excluding tubes packed separately.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide