Operating temperature 32-104 degrees f; internal/ebm battery type sealed, lead-acid, maintenance free;ups bypass automatic on overload or ups failure<4ms; transfer time to battery 0ms; overload capacity 125% for 10 minutes before transfer to bypass; 150% for 10 seconds before transfer to bypass.

pdf NSN 6130-01-525-9002 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
9.600 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.200 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Uninteruptable power supply; extended battery module (ebm)
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac pounds per hour wet single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz single operating power rqmt and 60.0 hertz single operating power rqmt
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
490.0 watts single power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
700.0 ac volt-ampere single power output
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
The time required to charge a battery(ies) to its rated capacity after a period of discharge.CWWB
Battery Recovery Time:
4.0
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
86.0
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Inavy: battery module
MRC:
The time required for a battery power supply to switch from standby mode to full rated output power.CXMN
Battery Switching Time:
Hot swappable
MRC:
--
NIIN:
015259002
MRC:
--
NATO Stock Number:
6130-01-525-9002
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
A39900
MRC:
--
INC:
67374
MRC:
--
IMM:
CX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6130-01-525-9002

An item that provides continuous backup power to electronic devices in the event of a utility power dip or blackout. it generally contains a battery and a power inverter that provides the necessary backup power in the event of a loss of normal input utility power. it may also contain a power line filter or power line conditioning devices. excludes power supplies without standby power, electrical power inverers, and batteries.

Recent Solicitations Most recent solicitations for NSN 6130-01-525-9002

End Date
Solicitation
Qty
Purchase Request
End Date:
2015-10-29
Solicitation:
SPE7L716T0340
Qty:
2
Purchase Request:
0060869730
End Date:
2015-09-14
Solicitation:
SPE7L715T6785
Qty:
2
Purchase Request:
0060237260
End Date:
2015-08-20
Solicitation:
SPE7L715T6258
Qty:
2
Purchase Request:
0059789274

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
36.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
10
PKG:
60Z0
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
XXX
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 10

Physical protection.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
060500
NMF Description:
Electrical Equipment Group
UFC:
81820
LTL:
No rating
LCL:
--
WCC:
72D
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 72D

Communications/electronics, other than sigint/ew or comsec repair parts and components.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

DLA History / Forecast Quantities

Land Supply Chain
05/1610/1603/1708/17
2.002.002.002.00

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide