6130-01-612-5594

Ruggedised Dc Uninterrupted Power Supply System email this page
ITAR Registered

Model or part number: SUVT40KH4B4S

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Built-in maint bypass; built-in static bypass; multi-function lcd status and control console; audible and visual alarms

pdf NSN 6130-01-612-5594 Datasheet

MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
813.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1499.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
559.0 millimeters
MRC:
The number of batteries required for operation.AEXR
Battery Quantity:
4
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Floor
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
400.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
230.0 ac volts and 400.0 ac volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz and 70.0 hertz single operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
47.0 hertz and 53.0 hertz single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.0 to 40.0 degrees celsius
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Full wave open bridge
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Three single power output
MRC:
The output waveform of the current at the output terminals.CWGS
Output Waveform And Current Type:
Sinusoidal ac single power output
MRC:
The time required to charge a battery(ies) to its rated capacity after a period of discharge.CWWB
Battery Recovery Time:
300.0
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Apc smart-ups vt
MRC:
--
NIIN:
016125594
MRC:
--
NATO Stock Number:
6130-01-612-5594
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
FIIG:
--
FIIG:
A39900
MRC:
--
INC:
52201
MRC:
--
IMM:
CX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6130-01-612-5594

An electrical equipment that is used to protect and condition the supply of ac and/or dc electrical power before it is consumed by a host(s). Its primary components are an internal battery pack, battery charger, inverter, and noise and surge suppression circuitry. The internal battery pack is used to sustain the host(s) when the ac or dc supply fails. External battery packs may be added in order to extend the period of sustenance. The ups is ruggedised to military standards for use in field environments.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8504408500
NAICS:
334419
End Use Class:
21400
SITC:
77121
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8504408500

Static Converters For Telecommunication Apparatus

End Use Code 21400

Telecommunications Equipment

Standard Intl. Trade Class (SITC) 77121

Static Converters (e.g., Rectifiers)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide