6140-01-203-4694

Storage Battery email this page

Model or part number: W-B-131

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Cold crank amps at 0 deg f-545;reserve capacity in minutes-135

Description

Lead-acid Battery NSN 6140-01-203-4694.

pdf NSN 6140-01-203-4694 Datasheet

MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Taper post
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
10.280 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.860 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.810 inches
MRC:
The composition of the electrolyte used in the battery.AEXT
Battery Electrolyte:
Acid
MRC:
An indication of whether or not a feature is included for the item to be operated in a specified depth of water without malfunction.AGEB
Fording Feature:
Not included
MRC:
The number of cells contained in the item.AQGQ
Cell Quantity:
6
MRC:
An indication of whether or not a nonspilling feature is included.AQHD
Nonspilling Feature:
Not included
MRC:
An indication of whether or not a charge indicator is included.AQHF
Charge Indicator:
Not included
MRC:
An indication of whether or not an electrolyte level indicator is included.AQHG
Electrolyte Level Indicator:
Not included
MRC:
The condition of the item when stored and/or shipped.AQHH
Storage/shipment Condition:
Wet charged
MRC:
An indication of whether or not an integral charging facility is included.AQHJ
Integral Charging Facility:
Not included
MRC:
The type of plate provided.ARGW
Plate Type:
Negative and positive
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
Indicates the type of design which describes the case.CWFH
Case Design Type:
Sealed
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
12.0
MRC:
--
NIIN:
012034694
MRC:
--
NATO Stock Number:
6140-01-203-4694
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T139-A
MRC:
--
INC:
00013
MRC:
--
IMM:
CX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

MSDS

Material safety data sheets
EXIDE CORP
Lead-acid Battery
EXIDE CORP
Lead-acid Battery
CELL ENERGY INC
Lead/acid Storage Battery

Formal Definition

Government issue definition of NSN 6140-01-203-4694

A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. the item may be furnished with integral charging facilities. for items which are composed of a single cell see cell, battery.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
HM
PKG:
50Z0
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
AAA
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) HM

Packaging and marking for hazardous materials shall comply with applicable requirements for performance oriented packaging contained in the international air transport association (iata) dangerous goods regulations or the international maritime dangerous goods code (imdg) and the code of federal regulations (cfr) title 29, title 40 and title 49. all performance test requirements shall be supported by certificates and reports attesting to the date and the results obtained from performance oriented packaging testing. the contractor, if not a self-certifier, shall be responsible for assuring that third party sources providing performance testing services are, in fact, registered with the department of transporation. the contractor's signed certification that the packaged configuration meets iata or imdg requirements shall be incorporated on the dd form 250, material inspection and receiving report, and other related acceptance documents if the dd form 250 is not used. all certificates and reports shall be available for inspection by authorized government representatives for a period of three years.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8507800002
NAICS:
335911
End Use Class:
20005
SITC:
77812
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8507800002

Storage Batteries, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77812

Electric Accumulators (storage Batteries)

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
060680
NMF Description:
Batteries Or Cell
UFC:
34100
LTL:
Rating variable
LCL:
--
WCC:
582
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 582

Batteries and parts (see 131), (vehicle parts).

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide