6145-00-162-0238

Electrical Power Cable email this page

Images

Reference images of this national stock number
Reference of NSN 6145-00-162-0238

Model or part number: 86743-85

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Optional yellow tracer third conductor

Description

Electric Cable NSN 6145-00-162-0238.

pdf NSN 6145-00-162-0238 Datasheet

MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
60.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.631 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
3
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
65 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
12 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
3 singles
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Green 1st position primary insulation third conductor
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinyl chloride 2nd position jacket cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
--
NIIN:
001620238
MRC:
--
NATO Stock Number:
6145-00-162-0238
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A077A0
MRC:
--
INC:
00232
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6145-00-162-0238

Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.

Recent Solicitations Most recent solicitations for NSN 6145-00-162-0238

End Date
Solicitation
Qty
Purchase Request
End Date:
2019-02-11
Solicitation:
SPE7M119T7394
Qty:
750
Purchase Request:
0077471247
End Date:
2018-05-18
Solicitation:
SPE7M118T302U
Qty:
750
Purchase Request:
0074275931
End Date:
2015-05-11
Solicitation:
SPE7M115TK769
Qty:
2250
Purchase Request:
0058325904

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
0.2000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
X
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
ZZ
PKG:
27A0
PRES MAT:
XX
WRAP MAT:
XX
ICQ:
000
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8544606000
NAICS:
335929
End Use Class:
20005
SITC:
77317
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8544606000

Insulated Electric Conductors For A Voltage Exceeding 1000 V, Nesoi

End Use Code 20005

Electric Apparatus

Standard Intl. Trade Class (SITC) 77317

Electric Conductors, For A Voltage Exceeding 1, 000 Volts, N.e.s.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
030310
NMF Description:
Cable Or Wire
UFC:
15080
LTL:
Rating variable
LCL:
--
WCC:
743
TCC:
Z
SHC:
9
ADC:
A
ACC:
H

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 743

Electrical cable.

Air Commodity (ACC) H

Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

DLA History / Forecast Quantities

Maritime Supply Chain
03/1606/1609/1612/1603/1706/1709/1710/1810/1810/19
575.00575.00575.00575.00575.00575.00575.00575.00695.00695.00

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide