6515-00-140-0888

Intravenous Injection Set email this page

Model or part number: 2C5402

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
70 in. O/a length,60 drops per ml,microdrip; non-vented w/o needle; used for administering parental solution from vented containers or non-air plastic containers

Description

Microset Administration Set NSN 6515-00-140-0888.

pdf NSN 6515-00-140-0888 Datasheet

MRC:
The number of components included in the item.AJJW
Component Quantity:
7
MRC:
A listing of those major components,outside the scope of an item of supply to be cataloged,as indicated by the name of the manufacturer,and the name and number of the item as identified by the manufacturer,and the number of each.AJKD
Nonsupply Items And Quantities:
Piercing device 1; calibrated drip chamber 1; roller clamp 1; flashball device w/injection site 1; end protectors 2; male needle adapter 1
MRC:
An indication of whether or not the item is free of living organisms.AKMX
Sterility:
Sterile
MRC:
An indication of the disposition of an item after initial use.ANGD
Disposition After Initial Use:
Disposable
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Intravenous inj set 7 comp microdrip 60 drops/ml non-vented 48s
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
D-day item for dod
MRC:
--
NIIN:
001400888
MRC:
--
NATO Stock Number:
6515-00-140-0888
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A23800
MRC:
--
INC:
14415
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6515-00-140-0888

An item used for administering intravenous solution and additives in controlled volume from standard solution bottles or bags. It may be used with blood filter unit for the administration of blood or blood deriuatives. For items which include a blood filter as a component, see blood recipient set, indirect transfusion. For items which include a cassette for intravenous administration, see cassette-intravenous injection set.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
5.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPACM00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9018908000
NAICS:
339112
End Use Class:
21610
SITC:
87229
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 9018908000

Other Instruments and Appliances Used In Medical, Surgical, Dental Or Veterinary Sciences, Nesoi

End Use Code 21610

Medicinal Equipment

Standard Intl. Trade Class (SITC) 87229

Instruments and Appliances Used In Medical, Surgical Or Veterinary Sciences, N.e.s.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
056680
NMF Description:
Dental/medical/surg Inst R Machine
UFC:
32570
LTL:
150.0
LCL:
--
WCC:
651
TCC:
Z
SHC:
9
ADC:
A
ACC:
M

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 651

Instruments, medical and surgical.

Air Commodity (ACC) M

Medical supplies, equipment, samples, records, etc..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide