About this product
Precision cosmetic/conventional cutting; needle,pc-5

pdf NSN 6515-01-257-4647 Datasheet

MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
18.000 inches
MRC:
The number of items contained in the unit package.AGUC
Unit Package Quantity:
12
MRC:
A designation indicating the size by which the item is commercially known and/or identified.AJXE
Size Designator:
3-0
MRC:
An indication of whether or not the item is free of living organisms.AKMX
Sterility:
Sterile
MRC:
The nominal length of a straight line which passes through the center of a needle,and terminates at the circumference.ANHM
Needle Diameter:
Any acceptable
MRC:
A measurement of the longest nominal dimension of a needle,in distinction from width.ANHP
Needle Length:
Any acceptable
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Nylon suture and steel, corrosion resisting needle
MRC:
Indicates the type of container with which the item is in direct contact.ANNW
Immediate Container Type:
Packet, foil, heat sealed
MRC:
The number of immediate containers.ANNX
Immediate Container Quantity:
12
MRC:
The number of items within each immediate container.ANNY
Quantity Within Each Immediate Container:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of an armed suture needle point.APRH
Armed Suture Needle Point Style:
Regular cutting edge
MRC:
The needle designation derived from the name of the designer or use for which the item is intended.APSH
Needle Design Designation:
Plastic surgery
MRC:
Indicates the type of end.APTD
End Type:
Single armed
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of an armed suture needle.APWL
Armed Suture Needle Style:
3/8 circle
MRC:
The specific arrangement of the fibers to form a strand.APZJ
Strand Fiber Arrangement:
Monofilament
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Suture nonabs plastic surgery nylon sz 3-0 18" l b2 3/8 cir pc-5 1s
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
--
NIIN:
012574647
MRC:
--
NATO Stock Number:
6515-01-257-4647
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A21900
MRC:
--
INC:
12952
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6515-01-257-4647

An item designed for stitching and thus securing tissues. It is designed of a material which cannot be dissolved and absorbed in such tissues.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9018320000
NAICS:
339112
End Use Class:
21610
SITC:
87221
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 9018320000

Tubular Metal Needles and Needles For Sutures and Parts and Accessories Thereof

End Use Code 21610

Medicinal Equipment

Standard Intl. Trade Class (SITC) 87221

Syringes, Needles, Catheters, Cannulae and The Like Used In Medical, Surgical Or Veterinary Sciences

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide