6520-01-139-9221

Electric Dental Laboratory Furnace email this page

Model or part number: 949-09-50

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
Air-fired suitable for staining and glazing porcelain prosthodontic devices; w/in radius of 10 m sonically notifies operator when desired temp is reached; muffle capable of w/standing temp of 1093 deg c; readable pyrometer w/scale calibrated from 0 deg to 2000 deg f; wt 4 kg

Description

Computerized Dental Laboratory Furnace NSN 6520-01-139-9221.

pdf NSN 6520-01-139-9221 Datasheet

MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+300.0/+2000.0 degrees fahrenheit
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
Indicates the type of unit.APQB
Unit Type:
Portable
MRC:
The frequency at which the item functions.APTT
Operating Frequency:
Between 50.0 hertz and 60.0 hertz
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Automatic temperature
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Furnace dental lab elec 300-2000 degrees f portable 120v 50/60hz ac
MRC:
--
NIIN:
011399221
MRC:
--
NATO Stock Number:
6520-01-139-9221
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T243-B
MRC:
--
INC:
20913
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Parts and Components for Electr Dental Laboratory Furnace NSN 6520-01-139-9221 Parts and components for this end application.

NSN Component Description
NSN 6685-01-510-5377 Heating Element Thermocouple
NSN 6640-01-510-5379 Laboratory Muffle Furnace
NSN 6520-01-510-5413 Dental Furnace Door

Formal Definition

Government issue definition of NSN 6520-01-139-9221

An item used for staining and glazing procelain prosthodontic devices.

Recent Solicitations Most recent solicitations for NSN 6520-01-139-9221

End Date
Solicitation
Qty
Purchase Request
End Date:
2019-12-30
Solicitation:
SPE2DH20T1166
Qty:
6
Purchase Request:
0082942500
End Date:
2019-07-09
Solicitation:
SPE2DH19T4892
Qty:
1
Purchase Request:
0080423830
End Date:
2018-03-05
Solicitation:
SPE2DH18T2515
Qty:
1
Purchase Request:
0073124305

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
11.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
ZZZZ
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9018490000
NAICS:
339114
End Use Class:
21610
SITC:
87219
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 9018490000

Other Instruments and Appliances, Used In Dental Sciences; and Parts and Accessories, Except Dental Drill Engines, Nesoi

End Use Code 21610

Medicinal Equipment

Standard Intl. Trade Class (SITC) 87219

Dental Instruments and Appliances, N.e.s.

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
000000
NMF Description:
No Nmfc Freight Description
UFC:
00000
LTL:
No rating
LCL:
--
WCC:
534
TCC:
Z
SHC:
9
ADC:
A
ACC:
M

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 534

Medical supplies (not requiring temperature control).

Air Commodity (ACC) M

Medical supplies, equipment, samples, records, etc..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide