6525-01-084-8924

Medical Radiographic X-ray Apparatus email this page

Model or part number: 9160M

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
2300 watts; bedside unit

pdf NSN 6525-01-084-8924 Datasheet

MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Mobile or portable
MRC:
Indicates the design type of the item.APGF
Design Type:
Mobile or portable
MRC:
The means used to operate the item.APHE
Operation Method:
Manual
MRC:
Indicates the type of control.AQZF
Control Type:
Console
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Single focus
MRC:
Indicates the type of rectification provided.BPKZ
Rectification Type:
Full-wave
MRC:
The means of cooling used to maintain the required operating temperature of the tube.CLPG
Tube Cooling Method:
Air
MRC:
Indicates the type of mount utilized to support the tube.CLPH
Tube Mounting Type:
Tube stand
MRC:
Indicates the type of mount utilized to support the tube stand.CLPR
Tube Stand Mounting Type:
Caster
MRC:
Indicates the type of radiographic timer provided.CLPX
Radiographic Timer Type:
Synchronous
MRC:
The means used for rectifying the transformer.CLQD
Transformer Rectification Method:
Self-rectifying
MRC:
The power output for which the transformer is rated.CLQF
Transformer Output Capacity:
1 to 39 ma at 100 kv peak
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
X-ray apparatus: low capacity port
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0 and 125.0 and 220.0 and 240.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
C/o control unit, digital timer, mobile tube stand, transformer, x-ray tube w/1 mm focal spot; requisition should state voltage and frequency, rating of utility power circuit
MRC:
--
NIIN:
010848924
MRC:
--
NATO Stock Number:
6525-01-084-8924
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T140-C
MRC:
--
INC:
06320
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Parts and Components for Med Radiographic X-ray Apparatus NSN 6525-01-084-8924 Parts and components for this end application.

NSN Component Description
NSN 5355-01-246-0094 Knob
NSN 5998-01-246-0125 Printed Circuit Board
NSN 5998-01-246-0126 Printed Circuit Board
NSN 5998-01-246-0127 Printed Circuit Board
NSN 5998-01-246-0128 Printed Circuit Board
NSN 5945-01-247-4963 Solid State Relay
NSN 5930-01-248-4784 Toggle Switch
NSN 5355-01-290-4636 Knob
NSN 5930-01-291-1185 Rotary Switch
NSN 5930-01-291-7043 Rotary Switch

Formal Definition

Government issue definition of NSN 6525-01-084-8924

A portable, mobile, or stationary device usually consisting of an x-ray tube, transformer, control, and associated devices designed for radiographic examination of patients.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
150.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9022140000
NAICS:
334517
End Use Class:
21610
SITC:
77421
USDA:
1
HITECH:
2

Schedule B Codes Definitions:

Schedule B 9022140000

Rays For Medical, Surgical, Or Veterinary Uses, Nesoi Apparatus Based On The Use Of X

End Use Code 21610

Medicinal Equipment

Standard Intl. Trade Class (SITC) 77421

Rays, Whether Or Not For Medical, Surgical, Dental Or Veterinary Use (including Radiography Or Radiotherapy Apparatus) Apparatus Based On The Use Of X

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
063560
NMF Description:
X-ray Machine Sub 1
UFC:
98185
LTL:
100.0
LCL:
--
WCC:
656
TCC:
Z
SHC:
9
ADC:
A
ACC:
M

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 656

X-ray apparatus and equipment.

Air Commodity (ACC) M

Medical supplies, equipment, samples, records, etc..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide