40000 watt; automatic collimator; bucky diaphram; spot film device; 24 by 24 cm front-end loading device; solid state

pdf NSN 6525-01-130-4930 Datasheet

MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Motor
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Adjustable non-skid footrest 1; compression-immobilization device 1; head clamp 1; patient grasp handles 1 pr; skidproof patient step 1; should rest 1; urological knee crutches 1 pr
MRC:
Indicates the design type of the item.APGF
Design Type:
Stationary
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
2
MRC:
Indicates the type of tube provided.AWGH
Tube Type:
Double focus, rotating anode fluoroscopic and double focus, rotating anode radiographic
MRC:
Indicates the type of table provided.BNBB
Table Type:
Tilting
MRC:
Indicates the type of rectification provided.BPKZ
Rectification Type:
Full-wave
MRC:
The means of cooling used to maintain the required operating temperature of the tube.CLPG
Tube Cooling Method:
Air
MRC:
Indicates the type of mount utilized to support the tube.CLPH
Tube Mounting Type:
Table and tube stand
MRC:
Indicates the type of mount utilized to support the tube stand.CLPR
Tube Stand Mounting Type:
Floor
MRC:
The means used for rectifying the transformer.CLQD
Transformer Rectification Method:
Self-rectifying
MRC:
The power output for which the transformer is rated.CLQF
Transformer Output Capacity:
To 300 ma at 150 kv peak
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
X-ray apparatus: high capacity radiographic and fluroscopic
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
190.0 and 270.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Use w/image intensifier; overhead tube mount; vertical cassette holder; for use in field assembly only
MRC:
--
NIIN:
011304930
MRC:
--
NATO Stock Number:
6525-01-130-4930
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T140-C
MRC:
--
INC:
06321
MRC:
--
IMM:
KX CX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Parts and Components for Radiographic And X-ray Apparatus NSN 6525-01-130-4930 Parts and components for this end application.

NSN Component Description
NSN 5930-01-156-9790 Push Switch
NSN 6525-01-178-3919 Printed Circuit Indicator Light
NSN 6210-01-178-3932 Printed Circuit Indicator Light
NSN 5961-01-184-1562 Thyristor Semiconductor Device
NSN 5930-01-219-2741 Sensitive Switch

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9022906000
NAICS:
334517
End Use Class:
21610
SITC:
77429
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 9022906000

Rays Parts and Accessories Of Apparatus Based On The Use Of X

End Use Code 21610

Medicinal Equipment

Standard Intl. Trade Class (SITC) 77429

Diagnostic Apparatus For Medical, Surgical, Dental Or Veterinary Sciences and Radiological Apparatus, N.e.s., Including Parts and Accessories Electro

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
063560
NMF Description:
X-ray Machine Sub 1
UFC:
98185
LTL:
100.0
LCL:
--
WCC:
656
TCC:
Z
SHC:
9
ADC:
A
ACC:
M

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 656

X-ray apparatus and equipment.

Air Commodity (ACC) M

Medical supplies, equipment, samples, records, etc..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide