6625-00-250-2008

Audio Test Set email this page

Model or part number: TS629EU

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

pdf NSN 6625-00-250-2008 Datasheet

MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
5.250 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
19.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
Between 103.5 volts and 126.5 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 400.0 hertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Audio level test panel
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Type no. Ts629eu
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum housing
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Measurement of audio ac current
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Input voltage range m40 dbm, 0.0077 v to p20 dbm, 7.746 v freq range 20 hz to 20 khz, porm 0.25 db and 50 hz to 10 khz porm 0.1 db input impedance, terminating 600 ohms, 10 pct, bridging 12.5 kilohms, 10 pct over-all accuarcy, 5 pct
MRC:
The number of alternating current phases.FAAZ
Phase:
Unable to decode
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
6.000 inches
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Enamel
MRC:
--
NIIN:
002502008
MRC:
--
NATO Stock Number:
6625-00-250-2008
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T228-A
MRC:
--
INC:
03617
MRC:
--
IMM:
TX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6625-00-250-2008

A test set primarily designed for use in making examinations of audio equipments, such as those used for public address, recording and/or reproducing. See also test set, telephone; test set, electron tube; generator, signal; multimeter; and test set, amplifier.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
2,150.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
F000004XE1
SPI Rev.:
SPC Mkg:
00
LVL_A:
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
XX
MOP:
51
PKG:
PRES MAT:
00
WRAP MAT:
XX
ICQ:
THK:
X
TOS:
UCL:

Packaging Codes Definitions:

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 00

No special marking.

Method of Preservation (MOP) 51

Watervaporproof bag, sealed.

Preservation Material (PRES_MAT) 00

No requirement.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9030908030
NAICS:
334515
End Use Class:
21160
SITC:
87479
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 9030908030

Parts and Accessories Of Articles Of Schedule B Subheading 9030.39

End Use Code 21160

Measuring, Testing, Control Instruments

Standard Intl. Trade Class (SITC) 87479

Parts and Accessories For Instruments and Apparatus (except Meters) Measuring Etc. Electrical Quanities and Devices Measuring Etc. Ionized Radiations

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide