6630-01-242-4050

Sodium-potassium Analyzer email this page

Model or part number: 210201

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards

About this product
If the analyzer does not contain an integral printer,it shall be capable of interfacing w/a commercially available external printer

pdf NSN 6630-01-242-4050 Datasheet

MRC:
A measurement from the bottom to the top of an object,in distinction from depth.ABRN
Height:
360.0 millimeters
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz or 60.0 hertz
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Potassium electrode, 1; sodium electrode, 1; reference electrode, 1; bottle of standard a, 2; bottle of standard b, 1; waste bottle, 1; bottle of reference filling solution, 1; bottle of test dye solution, 1; reference membrane assembly, 2; fluid path module, 1; bottle electrode rinse solution, 1; slide valve, 1; sample probe assemlby, 1
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Digital display screen and integral printer and self-calibration
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Analyzer potassium and sodium ion selective:
MRC:
The method by which an instrument performs the actual assay(s) of a sample/specimen.CYFV
Method Of Analysis:
Potentiometric/ion selective electrode
MRC:
Indicates the type of electrode(s) employed in the item to produce a specific ion assay of a sample/specimen.CYFX
Electrode Type:
Potassium/k+ and reference and sodium/na+
MRC:
The built in testing range for each type of test/assay that the analytical instrument is capable of performing.CYFY
Analysis Test/measurement Range:
Sodium 100-170 mmol/l in blood and 14-1400 mmol/l in undiluted urine; potassium 2-7 mmol/l in blood and 0.4-400 mmol/l in undiluted urine
MRC:
The amount,mass,volume,etc.,of a sample/specimen needed by the item to run a complete assay/test.CYFZ
Test Sample/specimen Size:
100 microliters of blood or 400 microliters of prediluted urine
MRC:
Indicates the type of sample/specimen the item is capable of ascertaining qualitative and/or quantitative assay determinations.CYHM
Test Sample/specimen Type:
Whole blood, serum, plasma, and urine
MRC:
A measurement between specified points on an item, in distinction from height.DPTH
Depth:
230.0 millimeters
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0 or 230.0
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
2.820 cubic feet
MRC:
The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
Unit Of Issue Weight:
29.00 pounds
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.WDTH
Width:
260.0 millimeters
MRC:
--
NIIN:
012424050
MRC:
--
NATO Stock Number:
6630-01-242-4050
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
A503U0
MRC:
--
INC:
38487
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Parts and Components for Sodium-potassium Analyzer NSN 6630-01-242-4050 Parts and components for this end application.

NSN Component Description
NSN 6630-01-332-2095 Sodium-potassium Probe Assembly

Formal Definition

Government issue definition of NSN 6630-01-242-4050

An automated computer controlled instrument employing ion-selective electrode for measuring sodium and potassium in whole blood, serum, plasma, and urine.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
9027803200
NAICS:
334516
End Use Class:
21600
SITC:
87446
USDA:
1
HITECH:
2

Schedule B Codes Definitions:

Schedule B 9027803200

Chemical Analysis Instruments and Apparatus, Nesoi

End Use Code 21600

Laboratory Testing Instruments

Standard Intl. Trade Class (SITC) 87446

Instruments and Apparatus For Physical Or Chemical Analysis, N.e.s.

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide