90 ft per minute average airflow; two prefilters meeting nbs standard for 75% retention; two 36 by 36 by 6 in. Filters certified 99.9% efficient at 0.3 micron particle size; fluorescent lighting; iv bar; two direct drive 1/3 hp motors; on-off switch for both motor and lights; maximum noise level 65 decibels; for use in preparation of intravenous solution

pdf NSN 6640-01-173-2461 Datasheet

MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
80.0
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac/dc
MRC:
The element,compound,or mixture of which the basic material is fabricated.AMSP
Basic Material:
Wood and plastic and steel, stainless
MRC:
The amount of apparent power,as distinguished from true power,for which the item is rated.AQYE
Volt-ampere Rating:
10.0
MRC:
A measurement of the longest dimension of a table,in distinction from width.ARDQ
Table Length:
75.000 inches
MRC:
A measurement taken at right angles to the length of a table,in distinction from thickness.ARDR
Table Width:
72.000 inches
MRC:
The rated horsepower of the electric motor.ASHK
Electric Motor Horsepower Rating:
0.333
MRC:
The element,compound,or mixture of which the cabinet is fabricated,excluding any surface treatment.AZSB
Cabinet Material:
Wood
MRC:
A measurement form the bottom to the top of a table,in distinction from depth.CLRH
Table Height:
23.000 inches
MRC:
A measurement of the longest dimension of the hood,in distinction from width.CLRS
Hood Length:
72.000 inches
MRC:
A measurement from the bottom to the top of the hood,in distinction from depth.CLRT
Hood Height:
35.000 inches
MRC:
The name and number of heating and/or air circulating unit controls provided.CLRZ
Heating/air Circulating Unit Control Name And Quantity:
Switch, motor, 1
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Hood fume laboratory 120/230 volt 50/60 hz ac
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0 or 230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 or 60.0
MRC:
--
NIIN:
011732461
MRC:
--
NATO Stock Number:
6640-01-173-2461
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T107-F
MRC:
--
INC:
38793
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Formal Definition

Government issue definition of NSN 6640-01-173-2461

A laboratory furniture device consisting of high efficiency particulate air filter, fluorescent light source, and full cabinet or bench top designed to maintain particle free air environment. Consists of horizontal or vertical air flow. Excludes hood, fume, laboratory.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
ZZZZ
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide