About this product
Dual chambered vertical carbon dioxide incubator; ea chamber indepently regulated,providing separate hot wall heating,humidity and co2 tension for microbiolocial cultures which require varying environments; automatic or manually controlled; flow rate from 0.06 to 0.44 liters per min

Description

Electric Incubator NSN 6640-01-187-6621.

pdf NSN 6640-01-187-6621 Datasheet

MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
18.000 inches
MRC:
An outside measurement taken at right angles to the length of an item,in distinction from thickness.ADJV
Outside Width:
20.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
17.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
24.000 inches
MRC:
An outside measurement from the bottom to the top of an item,in distinction from depth.AFMW
Outside Height:
76.000 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
700.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Temperature control dial and thermostat
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+10.0/+65.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
An outside measurement between specified points on an item,in distinction from height.BCXB
Outside Depth:
20.000 inches
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The number of shelves furnished with the item.BGZL
Shelf Quantity:
12
MRC:
An indication of whether or not the shelf(ves) is adjustable.BGZM
Shelf Adjustability:
Adjustable
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Gravity
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
The element,compound,or mixture of which the shelf is fabricated,excluding any surface treatment.BPYK
Shelf Material:
Steel, stainless
MRC:
The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
Cabinet Outer Wall Material:
Steel
MRC:
The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
Cabinet Inner Wall Material:
Steel, stainless
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
2
MRC:
The element,compound,or mixture of which the outer door is fabricated,excluding any surface treatment.BQMP
Outer Door Material:
Metal
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Not included
MRC:
The number of inner doors included.BQMS
Inner Door Quantity:
2
MRC:
The element,compound,or mixture of which the inner door is fabricated,excluding any surface treatment.BQMT
Inner Door Material:
Glass
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Not included
MRC:
The name assigned to the item by the government agency or commercial organization controlling the design of the item.CXCY
Product Name:
Incubator bacteriological co2 dual chamber 120 v 50/60 hz ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
--
NIIN:
011876621
MRC:
--
NATO Stock Number:
6640-01-187-6621
MRC:
--
Shelf Life:
N/A
MRC:
--
UOM:
--
MRC:
--
DEMIL:
No
FIIG:
--
FIIG:
T269-E
MRC:
--
INC:
17095
MRC:
--
IMM:
KX
Certified products icon

All Products Certified

Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.

Quality inspections icon

Quality | ISO 9001:2015 + AS9120B

We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC, ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.

Quality Commitment »

Shipping icon

Shipping

Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.

Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.

Packaging & Dimensions

MIL-STD codes: http://www.dla.mil/LandandMaritime/.../MILSTD2073Codes.aspx
Est. Pack Size
Est. Pack Weight
Est. Item Weight
Est. Item Dim.
Pack Size:
--
Paclk Weight:
--
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPACG00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
CUSH
MOP
CATEG.
PRES MAT
WRAP MAT
ICQ
THK
TOS
UCL
CUSH DUN:
ZZ
MOP:
ZZ
PKG:
ZZZZ
PRES MAT:
ZZ
WRAP MAT:
ZZ
ICQ:
THK:
Z
TOS:
UCL:

Packaging Codes Definitions:

LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

Method of Preservation (MOP) ZZ

See j.4.1.B.

Cushion Material (CUSH) ZZ

Special requirements. see specific instructions or drawings provided.

Preservation Material (PRES_MAT) ZZ

Special requirement. see specific instructions or drawings provided.

Import / Export

Schedule B Classification
Schedule B Number
NAIC National Association of Insurance Commissioners
End Use A classification system for U.S. exported and imported merchandise based on principal use rather than the physical characteristics of the merchandise. End-Use codes are assigned by the Bureau of Economic Analysis under the U.S. Department of Commerce.
SITC Commodity classification system defined by the United Nations.
USDA
HITECH
Schedule B:
8514100000
NAICS:
333994
End Use Class:
21180
SITC:
74131
USDA:
1
HITECH:
0

Schedule B Codes Definitions:

Schedule B 8514100000

Industrial Or Laboratory Furnaces and Ovens, Resistance Heated Types

End Use Code 21180

Industrial Machines, Other

Standard Intl. Trade Class (SITC) 74131

Resistance Heated Furnaces and Ovens

Freight

Universal / National freight and handling information
NMFC
Class
UFC
LTL
LCL
WCC
TCC
SHC
ADC
ACC
NMFC:
058280
NMF Description:
Scientific Instruments Noi
UFC:
33190
LTL:
200.0
LCL:
--
WCC:
652
TCC:
Z
SHC:
9
ADC:
A
ACC:
M

Freight Codes Definitions:

Cargo Type (TCC) Z

No special type of cargo code applicable.

Water Commodity (WCC) 652

Instruments, scientific.

Air Commodity (ACC) M

Medical supplies, equipment, samples, records, etc..

Air Dimensions (ADC) A

Shipment is not a consolidation and does not exceed 84 inches in any dimension.

Air Special Handling (SHC) 9

Other or no special handling required (sh)

Manufacturers

This NSN is registered to the following cage codes.
Compare Now »
Clear | Hide