Mflow range:2-30 lvp; constant flow: 2-30 lpm at pressures up to 7 psi; run time: 8 hr min.; operating temp: -4 to 113 deg f; humidity range: 0-95 percent rh, non-condensing; electronic pressure display; full function timing program; instant-fault function; programmable memory (up to 3 custom programs); keypad: accept, prog, time/press, run/hold; indicatiors: lld display, external rotometer, instant fault, low battery; 4.3 inches w x 0.3 h x 7.5 d; 12vdc at 3.4 amp
Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.
We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC,
ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.
Quality Commitment »
Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.
Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.
An assembly of equipment designed to collect samples of air suspected of being contaminated. May include electrically powered vacuum pump that draws a measured volume of air through a filter, tape or other such device, on which the sample(3) are collected and/or recorded to be later analyzed. The equipment may also be used with a telemetering device. Excludes analyzing kit, chemical.
Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.
Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.
No special marking.
Physical protection.
No requirement.
Chemical Analysis Instruments and Apparatus, Nesoi
Laboratory Testing Instruments
Instruments and Apparatus For Physical Or Chemical Analysis, N.e.s.
No special type of cargo code applicable.
Electrical appliances, small.
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).
Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Other or no special handling required (sh)
Code | Definition |
---|---|
FN | Factory New. Parts manufactured by the OEM and includes manufacturer certification. |
NE | New. Parts manufactured by the OEM. May include manufacturer certification or company certification. |
NS | New Surplus. New material item purchased from excess inventory. |
OH | Overhauled. Product has been rebuilt and tested in accordance with the manufacturer's specifications by a repair shop (MRO). |
SV | Serviceable product. |
AR | As Removed. Product removed from aircraft or platform with no guarentee on the functionality of the part. |
RP | Repairable. Product can be repaired by a MRO and be given a FAA 8130 or EASA Form 1 certification. |
Part Number | RNVC | RNAAC | DAC | CAGE |
---|---|---|---|---|
801012-100 | 2 | ZZ | E | 63882 |
610-7348095 ITEM 33 | 2 | ZZ | E | 33473 |
Name | No. Items | |||
---|---|---|---|---|
[You must be logged in to use lists] |