Model or part number: T-8000
About this product
Pnuematic temperature control which operates with a 25 psig maximum regulated air supply;contains two gages;one to monitor inlet the other to monitor control pressures;has a 0-4 psi sensitivity per deg. F.;temperature adjustment is concealed;surface mounted;ambient temperature operating ranges fromminus 10 deg. F. To +300 deg. F.;temperature included with dial markings of 2 deg. F. Per controling range;furnished with control are 4 1/8 in pipe plugs;2 elbows;2 oriface fittings;2 no 10x1 3/4 in mounting screws;capillary tube and bulb is stainless steel and fully compensated;bulb is 4 in long;capillary tube is 25 ft long
Indicating Thermostat NSN 6685-01-122-1705.
Factory New, New Material, New Surplus, Overhauled, Serviceable, Repairable, and AS Removed / Used material will be accompanied by a Certificate of Conformance, and any other documents/trace when applicable. We have a 7 year record retention.
We are committed to quality and follow an AS9120 quality management system. AeroBase Group is HAZMAT certified and registered with DDTC,
ITAR, and Aviation Suppliers Association (ASA). All products are 100% inspected.
Quality Commitment »
Delivery of IN-STOCK orders ship same-day when order is placed before 2:00 PM EST.
Delivery dates for NON-STOCK items are estimates based on current backlog and are subject to confirmation at the time of order.
A device composed of a control-actuating mechanism, a switch, and a graduated scale or other indicator. It is designed to measure and control temperature in ovens, furnaces, and the like, through perception of a sensing element connected to the control. Excludes switch, thermostatic and thermostat, flow control.
Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.
Packing shall be accomplished in accordance with table c.Ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
Delicate instrument.
Waterproof bag, sealed.
Ppp-c-795, cellular plastic film cushioning; or a-a-3129, open cell plastic cushioning; or ppp-c-1797, polypropylene foam cushioning; or a-a-59136, polyethylene foam cushioning.
Process Control Instruments and Apparatus For Temperature Control
Measuring, Testing, Control Instruments
Automatic Regulating Or Controlling Instruments and Apparatus, N.e.s.
No special type of cargo code applicable.
Instruments, medical and surgical.
Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps).
Shipment is not a consolidation and does not exceed 84 inches in any dimension.
Other or no special handling required (sh)
Code | Definition |
---|---|
FN | Factory New. Parts manufactured by the OEM and includes manufacturer certification. |
NE | New. Parts manufactured by the OEM. May include manufacturer certification or company certification. |
NS | New Surplus. New material item purchased from excess inventory. |
OH | Overhauled. Product has been rebuilt and tested in accordance with the manufacturer's specifications by a repair shop (MRO). |
SV | Serviceable product. |
AR | As Removed. Product removed from aircraft or platform with no guarentee on the functionality of the part. |
RP | Repairable. Product can be repaired by a MRO and be given a FAA 8130 or EASA Form 1 certification. |
Part Number | RNVC | RNAAC | DAC | CAGE |
---|---|---|---|---|
T-8000 | 1 | ME | 5 | 32242 |
T8000-2421 | 2 | ZZ | 5 | 1MN13 |
Name | No. Items | |||
---|---|---|---|---|
[You must be logged in to use lists] |