Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Light Emitting Diode
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Plastic
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.340 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.850 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.230 inches
MRC:
The ability of the lens to transmit light and allow visual perception.AEXK
Lens Transparency:
Translucent
MRC:
The specific purpose for which the item is designed.AFZC
Function For Which Designed:
Visible light emitting
MRC:
An indication of the internal basic form of the item.ALAS
Internal Configuration:
Point contact
MRC:
The symbol indicating the internal junction pattern of the item.ASCQ
Internal Junction Configuration:
Pn
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Gallium phosphide
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
2.2 forward voltage, dc
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
100.00 milliamperes forward current, dc
MRC:
The amount of electrical power that can be dissipated and the specific electrical characteristic.CTRD
Power Rating Per Characteristic:
180.0 milliwatts total power dissipation
MRC:
The hue,tint or shading produced by the item.CTRX
Color Tone Produced Per Source:
Red lens
MRC:
The measurement of luminous flux in a given direction per unit of solid angle.CTSB
Luminous Intensity:
2.0 millicandela
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
100.0 degrees celsius ambient air
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead