Part Number 005077-1

Wire Wound Fixed Resistor
Description

Electrical resistance: 10 kilohms

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
005077-1
Demil:
No
Shelf Life:
UOM:
NIIN:
000137260
NSN
National Stock Number:
5905-00-013-7260 5905000137260
TXT
Description:
Wire Wound Fixed Resistor
INC
INC
Item Name Code:
00010
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
10.000 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-0.020 to 0.020
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Encapsulated
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
The inductive or noninductive condition resulting from the method used in placing /winding/ wire on a form in the construction of electrical components.AARE
Reactance Characteristic:
Inductive
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.250 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.500 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
0.250 free air
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Axial terminal each end
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
19623-00577 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Similar Wire Wound Fixed Resistors

« Resistors Catalog
Compare Now »
Clear | Hide