Part Number 02-0001

Laboratory Centrifuge

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
02-0001
Demil:
No
Shelf Life:
UOM:
NIIN:
014953309

Part Information
Centrifuge laboratory 110/120v ac60hz sgl phase timer preprogram

NSN
National Stock Number:
6640-01-495-3309 6640014953309
TXT
Description:
Laboratory Centrifuge
INC
INC
Item Name Code:
17093
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.570 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The universal medical device nomenclature system code for this item.ALUE
Universal Medical Device Nomenclature System Code:
10778
MRC:
The minimum and maximum degrees of temperature an item can withstand without detrimental effect.AMPZ
Tempurature Range:
+5.0/+40.0 degrees celsius
MRC:
The means used to operate the item.APHE
Operation Method:
Electric
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
895.0
MRC:
An indication of whether or not a guard bowl is included.ATPT
Guard Bowl:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
110.0 and 120.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Timer is pre-programed; time and speed are pre-set at factory; weight is 14 pounds.