Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Spdt switch
NSN
National Stock Number:
TXT
Description:
Radio Frequency Transmiss Switch
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.650 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.900 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.0 gigahertz single frequency operating
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.140 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Nontransfer
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
0.880 inches single mounting facility pattern and 2.500 inches single mounting facility pattern
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
2.500 inches single mounting facility pattern
MRC:
The shortest distance between mounting centers parallel to the horizontal plane.AFDT
Shortest Horizontal Distance Between Mounting Centers:
0.880 inches single mounting facility pattern
MRC:
The intermediate distance between mounting centers parallel to the horizontal plane.AFDU
Intermediate Horizontal Distance Between Mounting Centers:
1.760 inches single mounting facility pattern
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Rf switching applications
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
1000.0 watts average single
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Solid state
MRC:
The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
Actuator Current Type And Rating In Amps:
0.1 dc
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
28.0
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Fail-safe
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
2
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
2
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position trapezoid single mounting facility pattern
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Spdt failsafe switch, rf connectors type n; terminals power connector/fast disconnect; freq 0-dc-1ghz; 28vdc; standard mounting holes; polarity not relevant to application for switches with logic
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy body and plastic body
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Designed to meet mil-s-3928
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 quick disconnect, female