All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
025-19982a
Demil:
No
Shelf Life:
UOM:
NIIN:
011069042

Part Information
Temperature pilot valve

NSN
National Stock Number:
4820-01-106-9042 4820011069042
TXT
Description:
Temperature Regulating Valve
INC
INC
Item Name Code:
05492
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Butt weld tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Beveled
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACLH
First End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Butt weld tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Beveled
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACMP
Second End Outside Diameter Tube Accommodated:
0.375 inches
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
180.000 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
4.812 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.625 inches
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Adjustable
MRC:
The basic design type of the thermostatic element used in transmitting the temperature of a liquid or gas.AEWJ
Thermostatic Element:
Integral w/valve
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between 130.0 degrees fahrenheit and 155.0 degrees fahrenheit
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Media, refrigerant r12, 22, 500, 502, and other non-corrosive refrigeration applications