Part Number 025-478

Laboratory Oven

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
025-478
Demil:
No
Shelf Life:
UOM:
NIIN:
011351961

Part Information
Adjustable air exhaust; continuously variable dial control

NSN
National Stock Number:
6640-01-135-1961 6640011351961
TXT
Description:
Laboratory Oven
INC
INC
Item Name Code:
17096
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
32.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
23.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
18.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
14.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
19.000 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
1450.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Thermostat
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+0.0/+240.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The number of shelves furnished with the item.BGZL
Shelf Quantity:
2
MRC:
An indication of whether or not the shelf(ves) is adjustable.BGZM
Shelf Adjustability:
Not adjustable
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Gravity
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Not provided
MRC:
An indication of whether or not cooling coils for below room temperature use are included.BNDW
Cooling Coils For Below Room Tempurature Use:
Not included
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Not included
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Not included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Laboratory Ovens